期刊文献+

CT引导下经皮肺穿刺活检的临床体会 被引量:8

下载PDF
导出
摘要 目的探讨CT引导下经皮肺穿刺活检对肺内病灶的诊断价值。提高肺部占位病变取材成功率和临床诊断准确率。方法本组43例肺部占位患者,行CT引导下经皮肺穿刺活检,分别行组织学检查及细胞学涂片检查,以术后病理为标准,分析肺穿刺活检的阳性率、成功率以及并发症的发生率。结果 43例全部取得有效标本,穿刺成功率100%,穿刺病理结果恶性肿瘤阳性率76.7%(33/43)。并发症:气胸2例(4.7%),痰中带血3例(7.0%),均较轻微,无严重并发症。结论 CT引导下经皮肺穿刺活检是一种安全、快捷准确的诊断方法。
作者 王卫星
出处 《实用心脑肺血管病杂志》 2012年第1期129-130,共2页 Practical Journal of Cardiac Cerebral Pneumal and Vascular Disease
  • 相关文献

参考文献8

二级参考文献32

  • 1许民生,韩修龄,王德杭.CT导向活检方法的研究及其临床应用[J].中华放射学杂志,1995,29(9):600-603. 被引量:112
  • 2李成州,肖湘生,刘士远,郭舜民,徐雪元.增强MRI对周围性肺结节的诊断价值[J].中国医学计算机成像杂志,1996,2(3):170-172. 被引量:13
  • 3Covey AM, Gandhi R, Brody LA, et al. Factors associated with pneumothorax and pneumothorax requiring treatment after percutaneous lung biopsy in 443 consecutive patients. J Vasc Interv Radiol, 2004, 15(5): 479.?A
  • 4Li H, Boiselle PM, Shepard JO, et al. Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: comparison of small and large pulmonary nodules. AJR Am J Roentgenol, 1996, 167(1): 105.
  • 5Tsukada H, Satou T, Twashima A, et al. Diagnostic accuracy of CT guided automated needle biopsy of lung nodules. AJR Am J Roentgenol, 2000, 175(1): 239.
  • 6Ko JP, Shepard JO, Drucker EA, et al. Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors? Radiol, 2001, 220(2): 554.
  • 7Yeow KM, See LC, Lui KW, et al. Risk factors for pneumothorax and bleeding after CT-guided percutaneous coaxial cutting needle biopsy of lung lesions. J Vasc Interv Radiol, 2001,12(11): 1305.?A?A
  • 8Westcott JL, Rao N, Colley DP. Transthoracic needle biopsy of small pulmonary nodules[J]. Radiology, 1997; (202) :97.
  • 9Larscheid RC, Thorpe PE, Scott WJ, et al. Percutaneous transthoracic needle aspiration biopsy:a comprehensive review of its current role in the diagnosis and treatment of lung tumors[J]. Chest, 1998 ; (114) : 704 - 709.
  • 10Laurent F, Latrabe V, Vergier B, et al. CT - guided transthoracic needle biopsy of pulmonary nodules smaller than 20mm: results with an automated 20 - gauge coaxal cutting needle[J].Clin Radio,2000;(55):281-287.