期刊文献+

三相SVC在电气化铁路电能质量治理中的应用 被引量:22

Application of Three-phase SVC in Power Quality Management for Electrified Railway
下载PDF
导出
摘要 随着电气化铁路的加速建设,电铁电能质量治理问题日益突出。针对电气化铁路负序电流和三相电压不平衡以及谐波问题,提出了一种基于三相静止无功补偿器(SVC)的电能质量综合治理方案。该方案不同于国内现有的两相式SVC和接入高压侧的三相SVC,将三相SVC接入牵引变电站的低压侧,重点补偿负序和无功,同时治理谐波。仿真结果表明,该方案能有效抑制负序、谐波和进行无功补偿。 With the accelerated construction of electrified railway, power quality management has become an increasingly important issue. To solve the problems of the serious negative sequence current, three-phase voltage unbalance and harmonics brought by electrified railway , a set of new program for power quality was proposed. This program is different from the domestic two-phase static var compensator (SVC) and the three-phase SVC accessed to high-voltage side of traction substation. The program based on the three-phase SVC accessed to the low-voltage side of the traction substation, which focus on compensating the negative sequence and the reactive power. Simulation results show that this program can effectively inhibit the negative sequence, harmonics and compensate reactive power.
出处 《电力系统及其自动化学报》 CSCD 北大核心 2011年第6期22-28,共7页 Proceedings of the CSU-EPSA
基金 国家十一五科技支撑计划(2009BAG12A09)
关键词 静止无功补偿器 电气化铁路 谐波 负序 电能质量 static var compendator(SVC) electrified railway l harmonics negative sequence power quality