摘要 光电容积脉搏波包含了人体丰富的生理、病理信息,对其进行实时监测可为临床研究和诊断提供科学的指导。开发了一套基于图形化虚拟仪器工程设计平台LabVIEW的光电容积脉搏波信号采集系统,可完成对该信号的实时采集、显示和数据存储。经过指端光电容积脉搏波信号的透射式采集实验,在LabVIEW前面板上准确显示出了该信号的波形,有助于对光电容积脉搏波进行深入分析。 Photoplethysmograph(PPG) includes abundant information of physiology and pathology. Real-time monitoring on it can provide scientific guidance for clinical research and diagnosis. A PPG signal acquisition system is introduced. This system is developed on an engineering design platform named LabVIEW, which is a virtual instrument based on graphic language. PPG signal acquisition system is used to collect, display and store data in real time. One experiment is carried out for this research, which gathers PPG signal from fingertip in transmission way. PPG waveform is exactly displayed on LabVIEW' s front-panel. These display results are helpful to analyze PPG in depth.
出处 《测控技术》 CSCD 北大核心 2011年第12期16-19,共4页 Measurement & Control Technology
关键词 光电容积脉搏波 采集系统 photoplethysmograph acquisition system
  • 相关文献

参考文献6

  • 1杨益民,李旭雯,罗志昌,张松.应用光电容积脉搏波法研制新型血流参数监护系统[J].中国医疗器械信息,2001,7(5):6-8. 被引量:14
  • 2高博,魏蔚,龚敏,王丽.脉搏血氧饱和度检测仪的研制[J].微计算机信息,2009,25(23):12-14. 被引量:6
  • 3Richard C Tissue hypoxia : How to detect, how to correct, how to prevent? [ J ]. Intensive Care Medicine, 1996,22 ( 1 ).
  • 4Sherebin M H, Sherebin R Z. Frequency analysis of the peripheral pulse wave detected in the finger with a photople- thysmograph[ J ]. IEEE Transactions on Biomedical Engineering, 1990,37 (3) 313 - 317.
  • 5HanoweU L, Eisele J H, Downs D. Ambient light affects pulse oximeters [ J ]. Anesthesiology, 1987,67 (5) : 864 - 865.
  • 6Shafqat K, Jones D P, Langford R M, et al. Filtering techniques for the removal of ventilator artefact in oesophageal pulse oximetry [ J ]. Medical & Biological Engineering & lomputing,2006,44 ( 8 ) :729 - 737.

二级参考文献8

  • 1刘进,魏蔚.经气管肺动脉血氧饱和度和(或)压力监测导管[P],中国:ZL031352227,2007,7,18.
  • 2Yasuhiro Saeki, Komin Takamura, Kazushige, et al. The measurement technique of human's bio-signals [C], Proceeding of the 28th IEEE EMBS Annual International Conference New York City, USA,Aug 30-Sept3,2006,1351-1354.
  • 3Wei Wei ,Zhaoqiong Zhu, Lunxu Liu, et al. A pilot Study of Continuous Transtracheal Mixed Venous Oxygen Saturation Monitoring[J], Anesth Analog 2005,101:440-44.
  • 4Ugnell H and Oberg PA, the tine-variable photoplethysmographic signal: dependence of the heart synchronous signal on wavelength and sample volume, Med.Eng.Phys.,17,571-578,1995.
  • 5Altera Corp., Cyclone Device Handbook[K], May 2003.
  • 6K. Shafqat, D.P.Jones, R.M.Langford, et al. Filtering techniques for the removal of ventilator artefact in oesophageal pulse oximetry [J], Med Bio Eng Comput,21 July 2006,44:729-737.
  • 7杨夏,王平,张军.基于FPGA的简化UART电路设计[J].微计算机信息,2008,24(23):226-227. 被引量:12
  • 8黄岚,田丰华,丁海曙,王广志,腾铁超.用近红外光谱对组织氧测量方法的研究[J].红外与毫米波学报,2003,22(5):379-383. 被引量:35