摘要
以广州台山1000MW超超临界机组为例,分析了超超临界机组过热汽温控制的动态特性,论述了过热汽温控制中的燃水比和减温水控制策略,并根据实例进行了详细的分析和研究。
Guangzhou Taishan 1000MW supercritical unit , as an example,the paper analyzes dynamic characteristic of the superheated steam temperature control for supercritical Unit of dynamic characteristic and discusses control strategy to superheated steam temperature fuel - water ratio and desuperheating water control. Finally, according to the practical examples, the paper carries out deliberate analysis and research.
出处
《贵州电力技术》
2011年第12期15-17,共3页
Guizhou Electric Power Technology
关键词
超超临界机组
燃水比
过热汽温
减温水
supercritical unit
fuel - water ratio
superheated steam temperature
desuperheating water