摘要
结合调度工作实际,对蚌埠地区电网中两座小热电厂的接线方式、继电保护及安全自动装置配置,以及机组大、小处理情况下的运行方式安排、功率平衡问题进行讨论,并分析了小电厂接入电网存在的问题,提出了具体的解决方法。
Combining the actual scheduling work, the paper describes the way of grid connection, relay protection, automatic safety device configuration in two small power plants in Bengbu area, and discusses arrangements of operation mode and power balance under large or small units, and analyses the problems the small power plant connect to power grid, proposes specific solutions.
出处
《安徽电力》
2011年第4期55-57,共3页
Anhui Electric Power
关键词
蚌埠电网
小热电厂
并网
运行方式
分析
Bengbu power grid
small thermal power plant
grid connected
operation mode
analysis