摘要
为了考察UV/H2O2工艺对微量有机物的去除效果,在砂滤池出水后接UV/H2O2高级氧化中试设备,并投加了特征污染物(阿特拉津、臭味物质2-MIB与Geosmine)。结果表明,UV/H2O2工艺对Geosmine去除效果最好,去除率能达到90%以上,对MIB和阿特拉津的去除效果比较接近,去除率均在50%以上,对UV254的去除率为20%~38%。在UV/H2O2工艺中无溴酸盐生成。
To study the removal efficiency of UV/H2O2 process on micro organic pollutants, UV/H2 O2 pilot equipment was used to treat the sedimentation effluent dosed with target pollutants (including Atrazine, odor matter 2 - MIB, and Geosmine). The results showed : UV/H2 O2 had the best efficiency on removing Geosmine with the removal rate over 90%. The removal effect of MIB and Atrazine was alike, and the removal rates both reached over 50%. The removal rate of UV254 was 20-38%. No bromate was formed in the UV/H2O2 process.
出处
《给水排水》
CSCD
北大核心
2012年第1期119-122,共4页
Water & Wastewater Engineering
基金
住房和城乡建设部研究开发项目(2011-K7-6)
上海市科学技术委员会科研计划项目(1023 120 1002)