结合地铁防排烟系统的组成和特点,分析了地铁防排烟系统调试前应具备的条件,介绍了地铁工程防排烟系统测试的方法,对调试中出现的问题提出了相应的解决方案,以期指导实践。
Combining with the composition and features of subway smoke control and extraction system,the paper analyzes conditions for the adjustment of subway smoke control and extraction system,introduces the testing method of smoke control and extraction system of subway engineering,and proposes corresponding solutions to the problems occurring in the adjustment,with a view to guide practice.
出处
《山西建筑》
2012年第2期131-132,共2页
Shanxi Architecture
关键词
防排烟
系统调试
地铁
smoke control and extraction
system adjustment
subway