摘要 在高压高频复合电场和过滤器联合作用对空气进行净化时,建立了可吸入气溶胶颗粒凝并的数学物理模型,得出了半值时间tH的表达式,同时,设计了一套试验装置对理论模型进行验证.研究结果表明,随着可吸入气溶胶颗粒初始浓度的增加,半值时间tH减少,气溶胶颗粒浓度减半所需的换气次数减少.与只有过滤器作用时的理论模型比较,高压高频复合电场和过滤器联合作用时的半值时间tH减少了,缩短了空气的净化时间.研究结果为工程设计提供了理论和试验基础. A mathematical and physical model of the inhalable aerosol particles coagulation under the joint action of high voltage and high frequency complex electric fields work together with the filter is developed and solution of the half time tn is obtained. At the same time,a set of experimental device is built to verify the theoretical model. The results show that the half time tH drops while the initial concentration of the inhalable aerosol particles reduces and the air change rate required for halved concentration reduces with increasing initial concentration. Compared with the theoretical filter model, the half time t H is reduced nearly half when the high voltage and high frequency complex electric fields work together with the filter. The time of air purification is greatly shortened. The research provides the theoretical and experimental foundation for engineering design.
出处 《东华大学学报(自然科学版)》 CAS CSCD 北大核心 2011年第6期774-777,共4页 Journal of Donghua University(Natural Science)
关键词 复合电场 过滤器 气溶胶 凝并 半值时间 complex electric fields filter aerosol coagulation half time
  • 相关文献

参考文献10

  • 1沈晋明.室内污染物与空气品质评价[J].通风除尘,1995,14(4):10-13. 被引量:78
  • 2FREY A H. Change in room aerosol concentralion by in duct complex electric fields[J]. J of Environ Sci, 1984, 27 (1):34-36.
  • 3薛志杰,顾平道,杨子兵.高压高频复合电场作用下气溶胶凝并效果的实验研究[J].洁净与空调技术,2007(2):17-19. 被引量:1
  • 4WATANABE T, TOCH1KUBO F, KO1ZUMI Y, et al. Submicron particle agglomeration by an electrostatic agglomerator [J]. Journal of Electrostatics, 1995, 34(4) :367-383.
  • 5KILDESo J,BHATIA V K, IAND L, et al . An experimental investigation for agglomeration of aerosols in altemating electric field [J]. Aerosol Sci and Tech, 1995,23(4):603-610.
  • 6WANG L Z, ZHANG X R, ZHU K Q. An analytical expression for the coagulation coefficient of bipolarly charged particles by an external electric field with the effect of coulomb force [J]. Journal of Aerosol Sci, 2005, 36(8) :1050-1055.
  • 7张向荣,王连泽,朱克勤.外电场对荷电颗粒静电凝聚的影响[J].清华大学学报(自然科学版),2005,45(8):1107-1109. 被引量:14
  • 8TAN B H, WANG L Z, ZHANG X R. The effect of an external DC electric field on bipolar charged aerosol agglomeration [J]. Journal of Electrostatics, 2007, 65(2) ; 82-86.
  • 9TAN B H, WANG I. Z, WU Z N. An approximate expression for the coagulation coefficient of bipolarly charged particles in a alternating electric field [J]. Journal of Aerosol Sci, 2008, 39 (9), 793-800.
  • 10曹阳,郎四维.介绍一种新型空气自净系统[J].建筑科学,1998,14(1):58-61. 被引量:8

二级参考文献13

  • 1沈晋明,毛继传,孙光前.上海办公大楼空气品质客观评价[J].通风除尘,1995,14(4):14-17. 被引量:51
  • 2Fuchs N A. The Mechanics of Aerosols [M]. Oxford: Pergamon Press, 1964.
  • 3WANG Lianze, ZHANG Xiangrong, ZHU Keqin. An analytical expression for the coagulation coefficient of bipolarly charged particles by an external electric field with the effect of Coulomb force [J]. Journal of Aerosol Science, 2004 (accepted).
  • 4Adachi M, Okuyama K, Kousaka Y. Electrostatic coagulation of bipolarly charged aerosol particles [J]. Journal of Chemical Engineering of Japan, 1981, 14(6): 467-473.
  • 5Oron A, Seinfeld J H. The dynamic behavior of charged aerosols. Part II. Numerical solution by the sectional method [J]. Journal of Colloid and Interface Science, 1989, 133(1): 66-79.
  • 6Eliasson B, Egli W. Bipolar coagulation-modeling and applications [J]. Journal of Aerosol Science, 1991, 22(4): 429-440.
  • 7Vemury S, Janzen C, Pratsinis S E. Coagulation of symmetric and asymmetric bipolar aerosols [J]. Journal of Aerosol Science, 1997, 28(4): 599-611.
  • 8Smoluchowski M V. Versuch zur mathematischen theorie der koagulationskinetik kolloider losungen [J]. Zeitschrift fur physikalische Chemie, 1917, 92: 129-168.
  • 9Zebel G. Zur Theorie des Verhaltens elektrisch geladener Aerosole [J]. Kolloid-Zeitschrift, 1958, 157: 37-50.
  • 10COSA\TRON空气自净装置应用研究报告[R].中国建筑科学研究院,2001.7.

共引文献97

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部