摘要
研究了具有除湿功能的热泵空调系统 ,导出了由于间歇运行的停机过程造成的潜冷量损失和修正后的季节用能效率 ,并分析了环境温湿度及系统特性对停机潜热损失及季节能效比的影响。
The loss of the latent heat/cool capacity of a on off air conditioner or heat pump are discussed considering influence the loss of latent heat/cool capacity the seasonal energy efficiency ratio(SEER)of unitary air conditioners and heat pumps has also been derived.From the research results the relationships between the SEER and dry and wet bubble temperature,the loss of the latent capacity and wet bubble temperature can be obtained.
出处
《太阳能学报》
EI
CAS
CSCD
北大核心
2000年第1期29-34,共6页
Acta Energiae Solaris Sinica
基金
国家重点自然科学基金
天津市青年基金
关键词
热泵
空调
季节能效比
除湿
heat pump,air conditioner,SEER,removing humidity