摘要
针对神华河北国华定洲发电有限责任公司660MW直流锅炉启动时蒸汽温度偏高的问题,经分析,认为蒸汽温度偏高的主要原因为水冷壁产生的蒸汽量太小,并提出减小过量空气系数、降低一次风速度、增加燃料燃尽率等解决措施。
Aiming at Shenhua Hebei Guohua power generation Co. Ltd. , superheated steam temperature during: start-up of 660 mw once-through boiler, this paper considers the main reason for the high temperature steam for water wall produce steam content is too small, and proposes reducing excess air coefficient, lower a wind speed, increase fuel burn rate,and other measures.
出处
《河北电力技术》
2011年第6期53-54,共2页
Hebei Electric Power
关键词
超临界锅炉
启动
蒸汽温度
蒸汽量
supercritical boiler
start - up
steam temperature
steam content