摘要 材料替代和一回路水化学控制是降低活化腐蚀产物源项的主要措施。本文介绍M310、AP1000和EPR三种压水堆核电站一回路水化学优化情况,比较三种压水堆一回路活化腐蚀产物源项,分析探讨水化学优化对源项降低的影响,最后对国内压水堆核电站一回路水化学优化提出建议。 Material substitution and primary system water chemistry control are the main measures for the reduction of the activation and corrosion products source term.In this article,the optimization of primary side water chemistry of M310,AP1000 and EPR were introduced,the influence of water chemistry optimization on the reduction of source term were analyzed by comparing the source terms of the activation and corrosion products of three PWRs.Finally,the suggestions of primary side water chemistry optimization for domestic PWR were proposed.
出处 《辐射防护》 CAS CSCD 北大核心 2012年第1期8-14,20,共8页 Radiation Protection
关键词 压水堆 活化腐蚀产物 水化学优化 材料替代 源项 PWR activation and corrosion products water chemistry optimization material substitution source term
  • 相关文献

参考文献10

  • 1Sanmen Nuclear Power Company Ltd. Sanmen nuclear power plant phasel units 1&2 preliminary safety analyses report[ R ]. 2008.
  • 2Taishan Nuclear Power Company Ltd. Taishan nuclear power plant phasel units l&2 preliminary safety Analyses Report[R]. 2009.
  • 3Rocher A. Bergcr M.LImpact of main radiological pollutants on contamination risks (ALARA) optimization of physico chemical environment and retention technics during operation and shutdown [ C ]. EDF,Portoroz Workshop. Session 2.2004.
  • 4AREVA( 阿海珐集团 ). Reactor coolant chemical characteristics and specifications. Taishan Nuclear Power Station(Rev.A)[ R ]. 2008.
  • 5王琳.秦山第二核电厂1和2号机组长循环燃料管理论证[R].一回路水化学论证报告.2009.
  • 6高惠斌,张乐福,方军.停堆氧化运行中主回路活化腐蚀产物的迁移与控制[J].核动力工程,2009,30(2):78-81. 被引量:20
  • 7顾景智,杨茂春,陈德淦,黄荣许.大亚湾核电站辐射源项控制的实践[J].辐射防护,2004,24(3):227-232. 被引量:16
  • 8Westinghouse Electric Company LLC. AP1000 Chemistry Manual(Rev.0)[R]. 2010.
  • 9Electric Power Research Institute (EPRI). PWR Zinc application guidelines 1013420(Rev.0) [R].2006.
  • 10Electric Power Research Institute (EPRI). Experience with Zinc injection in European PWRs 1003378[R]. 2002.

二级参考文献9

  • 1Burrill K A.关于堆内水化学与腐蚀产物沉积的综合实验研究[J].英国核能学会,反应堆系统水化学,1977.
  • 2Odar S. Fundamental Aspects of Water Chemistry in the Primary System of PWRs[M]. Paris, AREVA, 2007.
  • 3Cohen E Water Coolant Technology of Power Reactors, Gordon and Breach[M]. New York, 1969.
  • 4Allinei P G.Mesuure de Contamination des Circuits de Gravelines 5 pendant Larret a fin ducvcle.1992
  • 5Garbertt K.Overview of the Impact of Stellite Removal on Radiation Fields in KWU PWRs.The Sixth Conference of Water Chemistry of Nuclear Reactor System,1992
  • 6.法国电力公司安全简报.C''EST ARRIVE DAN LES CENTRALES.No.50.04/2000[Z].,..
  • 7洪蔚.209大修辐射防护总结报告.内部资料[Z].,2002..
  • 8顾景智.核电站主泵停运控制核素的选择[J].辐射防护,2000,20(3):185-188. 被引量:6
  • 9樊治国,问清华,李睿容,罗惠勇,张涵,张文发.大亚湾核电站1994~2002年职业性照射个人剂量监测和评价[J].辐射防护,2004,24(3):206-210. 被引量:11

共引文献33

同被引文献130

引证文献29

二级引证文献61

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部