摘要
采用UV-Fenton体系预处理四氢呋喃废水,实验结果表明,pH值、反应时间、Fe2+和H2O2投加量等因素对处理效果有较大的影响。实验确定的最佳反应条件为:原水pH=5,Fe2+投加量2.5 mmol/L,H2O2投加量12 mmol/L,反应时间90 min,连续曝气,在此条件下,COD去除率可达85%左右。经UV-Fenton体系处理后,废水的B/C值由0.16增至0.47,可生化性提高,可满足后续生化处理的要求。
UV/Fenton process was used as a pretreatment method to treat tetrahydrofuran wastewater.Experimental results showed that the influencing factors for the reaction mainly included pH,reaction time,the dosage of Fe2+ and H2O2.Under the conditions of continuous aeration,the optimum reaction conditions of pH,dosage of Fe2+,dosage of H2O2,reaction time were 5,2.5 mmol/L,12 mmol/L and 90 min,respectively.Under the optimum conditions,the removal rate of COD could be up to 85%.After treatment,the B/C value of the wastewater increased from 0.16 to 0.47,and the biodegradability was improved greatly,and the effluent could satisfy the requirements of follow-up biochemical treatment process compeletely.
出处
《环境工程学报》
CAS
CSCD
北大核心
2012年第1期237-241,共5页
Chinese Journal of Environmental Engineering