期刊文献+

ZrO_2基电化学NO_x传感器非活化电极浆料的研究 被引量:3

Study of inactivated electrode paste used for ZrO_2-based NO_x sensor
下载PDF
导出
摘要 ZrO2基电化学NOx传感器是对柴油机尾气中NOx含量进行检测的重要元件。文中研究了NOx传感器用非活化电极浆料配方,通过调整配方中的造孔剂含量和Au含量,比较传感器的氮氧化物测量泵电流Ip2的零点偏移量,得出造孔剂含量为4%、Au含量为0.4%~0.8%的浆料配方满足NOx传感器使用要求。 Electrochemical NOx sensors based on ZrO2 is the most reasonable choice for detection of diesel exhaust NOx concentration. This paper studied the formula of the inactivated electrode paste used for NOx sensors, adjusted the content of pore-forming agent and Au, compared the offset current Ip2, and obtained the best formula. It is found that when the pore-forming agent content is 4% and Au content is 0.4%-0.8%, the requirements of NOx sensor can be met.
出处 《武汉科技大学学报》 CAS 2012年第1期41-43,共3页 Journal of Wuhan University of Science and Technology
基金 江苏省科技支撑计划(工业)项目(BE2010024)
关键词 NOx 传感器 非活化电极 浆料 NOx sensor inactivated electrodel paste
  • 相关文献

参考文献8

二级参考文献54

  • 1江妙瑞 M.t.weller.第六届全国固态离子学学术讨论会论文集[M].,1992.242.
  • 2Jenkins R A, Gill B E. Determination of oxides of nitrogen(NOx)in cigarette smoke by chemiluminescent analysis [ J ]. Anal.Chem., 1980, 52(6) : 925 - 928.
  • 3Health Canada-official method T-110. Determination of oxides of nitrogen in mainstream tobacco smoke[ S]. 1999.
  • 4Norman V, Ibrig A M, Larson T M, et al. The effect of some nitrogenous blend components on NO/NOx and HCN levels in mainstream and sidestream smoke [J]. Beitra. Tabakforsch. Int.,1983, 12(2) : 55 - 62.
  • 5Parrish M E, Lyons-Hart J L, Shafer K H. Puff-by-puff and intrapuff analysis of cigarette smoke using infrared spectroscopy[ J ]. Vibrational Spectroscopy, 2001, 27: 29- 42.
  • 6Makoto Nonomura, Toshiyuki Hobo. Development of automatic continuous analytical apparatus of sulfur oxides, nitrogen oxides and hydrogen chloride in flue gas by ion chromatograph [ J ]. Kenkyu Hokoku-Tokyo-toritsu Sangyo Gijutsu Kenkyusho, 2000, 3:47 -50.
  • 7De Santis F, Dogeroglu T, Fino A, et al. Laboratory development and field evaluation of a new diffusive sampler to collect nitrogen oxides in the ambient air[J]. Analytical and Bioanalytical Chem.,2002, 373(8) : 901 - 907.
  • 8Neurath G, Dunger M. Measurement of nitrogen oxides in tobacco smoke by means of the chemiluminescence method[ J]. Iarc. Sci.Publ., 1972, 3: 134.
  • 9Osdene T S, Wickham J E, Meyer L F, et al. The AA-2 chemiluminescence analyzer as a readout for NO in the gas phase of cigarette smoke[R]. Philip Morris USA Research Center, 1974.
  • 10Cumming E M. A smoking machine attachment for the analysis of carbon monoxide, carbon dioxide and nitric oxide in the vapor phase of cigarette smoke[J]. Beitr. Tabakforsch. Int., 1975, 8(3) : 153- 157.

共引文献22

同被引文献19

引证文献3

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部