摘要 加速度传感器以其轻便、客观、精确等特点,在人体体力活动测量与评价中被广泛使用。LivePod LP2是一款国产新型加速度传感器,它基于3轴加速度MEMS传感器技术,采用人体动作智能模糊识别模型和个性化能耗模型测量人体运动中的能量消耗。对LivePodLP2在测量人体运动能量消耗的信度和效度水平进行了验证。26名受试者在4个不同部位佩戴LivePod LP2,在3种速度下(4km/h、6km/h、8km/h)运动。通过计算ICC,发现其值处于0.978~0.997;采用相关分析、配对样本t检验以及Bland-Altman分析法等方法对仪器和MAXII测量数据分析表明:LivePod LP2佩戴于右侧臀部上方,在慢跑速度水平下效度水平最高。LivePod LP2可以用于记录体力活动能量消耗,在日常应用中,用户可以选择将LivePod LP2固定于腰部来监测运动能量消耗情况。 Due to accelerometers' characteristics such as light,objective and accurate,they are widely used in physical activity measurement and evaluation.LivePod LP2 is a domestic new accelerometer,which is based on three axis acceleration MEMS sensor technology,using intelligent fuzzy recognition Model of human body movements and Individuation Consume Energy measurement Model to identify human body energy expenditure in movements.In this paper,the reliability and validity of LivePod LP2 in measurement are verified.26 subjects wearing LivePod LP2s in four different postions motioned at three speeds(4,6,8 km/h).Through calculation of ICC of every minute on each level,we evalue the agreement of LivePod LP2,and we can see the ICC value is in 0.978 ~ 0.997 indicating high reliability level;By using correlation analysis,matching sample t-test and Bland-Altman analysis between the instrument and MAXⅡ,we can see:at all three speeds,criterion validity of LivePod LP2 is between 0.7 and 0.8,and the validity of LivePod LP2 wearing in the loins when jogging is the highest.LivePod LP2 can be used to predict the energy expenditure in physical activity.During daily application,the user can fix LivePod LP2 to the right waist to monitor movement energy expenditure.
出处 《体育科学》 CSSCI 北大核心 2012年第1期48-53,共6页 China Sport Science
关键词 LivePod LP2 人体运动 能量消耗 信度 效度 Live Pod LP2 energy expenditure reliability validity
  • 相关文献

参考文献26

  • 1戴剑松,李靖,顾忠科,孙飙.步行和日常体力活动能量消耗的推算[J].体育科学,2006,26(11):91-95. 被引量:51
  • 2戴剑松,孙飙.体力活动测量方法综述[J].体育科学,2005,25(9):69-75. 被引量:66
  • 3汤强,王香生,盛蕾.体力活动测量方法研究进展[J].体育与科学,2008,29(6):79-86. 被引量:55
  • 4知康科技[EB/OL].http://www.beingpower.com.
  • 5知康科技产品中心[EB/OL].http://www.beingpower.corn/goods.php?id=1.
  • 6BRAGE S, WEDDERKOPP N, FRANKS P W,et al. Reexami- nation of Validity and Reliability of the CSA Monitor inWalking and Running[J]. Med Sci Sports Exe,2002,35(8) : 1447-1454.
  • 7CAAPERSEN C J, POWELL K E, CHRISTENSON G M. Phys- ical activity, exercise and physical fitness.. Definitions and distinc- tions for health-related research[J]. Public Health Rep, 1985, 110:126-131.
  • 8CHE-CHANG YANG, YEH-LIANG HSU. A review of aceeler- ometry-based wearable motion detectors for physical activity monitoring [J]. Sensors, 2010,10 : 7772-7787.
  • 9D JOHN. Comparison of activity counts from the actigraph GT3X and GT1M [R]. International Congress on Physical Activity and Public Health (ICPAPH),2010.
  • 10ESLIGER D W, TREMBLAY M S. Technical reliability assess- ment of three accelerometer models in a mechanical setup[J]. Med Sci Sport Exe, 2006,38(12) : 2173-2181.

二级参考文献174

  • 1冯建英.一种测定能量消耗的新技术──双标水法[J].中国运动医学杂志,1996,15(3):203-205. 被引量:11
  • 2Fletcher GF, Blair SN, Blumenthal J, Caspersen C, Chairman B, Epstein S, et al. Statement on exercise. Benefits and recommendations for physical activity programmes for all Americans. A Statement for health professionals by the Committee on Exercise and Cardiac Rehabilitation of the Council on Clinical Cardiology, American Heart Association. Circulation 1992; 86:340-344.
  • 3Yves Schutz, Roland L. Weinsier, Gary R. Hunter. Assessment of free-living physical activity in humans: an overview of currently available and proposed new measures. Obes Res. 2001,9:368 -379.
  • 4Livingstone M. B. E. , Robson P. J. , Wallace J. M. W. , Mckinley M. C. How active are we Levels of routine physical activity in children and adults. Proceeding of the Nutrition Society. 2003; 62; 681-701.
  • 5Luc Vanheesa,d, Johan Lefevreb, Renaat Philippaertsc, et al. How to assess physical activity How to assess physical fitness Eur J Cardiovasc Prev Rehabil 2005; 12 : 102- 114.
  • 6Schoeller DA, Ravussin E, Schutz Y, Acheson KJ, Baertschi P, Jequier E. Energy expenditure by doubly labelled water: validation in humans and proposed calculation. Am J Physiol 1986; 250(Suppl 5) :R823-R830.
  • 7Klein PD, James WPT, Wong WW, et al. Calorimetric validation of the doubly- labelled water method for determination of energy expenditure in man. Human Nutr Clin Nutr 1984; 38:95-106
  • 8Schoeller DA, Webb P. Five-day comparison of the doubly labeled water method with respiratory gas exchange. Am J Clin Nutr 1984; 40:153-8
  • 9Jones PJ, Winthrop AL, Schoeller DA, et al. Validation of doubly labelled water for assessing eriergy expenditure in infants. Pediatr Res 1987; 21 (3) : 242-6
  • 10Black AE, Cole TJ. Within- and between-subject variation in energy expenditure measured by the doubly labelled water technique: implications for validating reported dietary energy intake. Eur J Clin Nutr 2000; 54:386 -394