摘要
主要针对火力发电厂建筑物防爆泄压设计中常用的防爆泄压措施,建筑物泄压面积的计算,建筑物泄压开窗面积的确定等问题展开讨论,以供火力发电厂工程设计同行参考。
The paper makes a discussion on anti-explosion and pressure-relief measures commonly used in buildings of thermal power plant, calculation of building pressure-relief area, determination of window area for building pressure-relief and other issues, which can be considered as reference in similar projects.
出处
《红水河》
2011年第6期24-27,共4页
Hongshui River
关键词
火力发电厂
有爆炸危险的建筑
防爆泄压设计
泄压面积
thermal power plant
building with explosion risk
anti-explosion and pressure-relief design
pressure-relief area