[目的]测定厚朴叶多糖铁复合物中铁的含量。[方法]从厚朴叶中提取多糖,在碱性条件下,厚朴叶多糖与氧化铁反应合成厚朴叶多糖铁(Ⅲ)复合物(LPC)。其中的铁(Ⅲ)含量用邻菲啰啉紫外分光光度法进行测定。[结果]在铁(Ⅲ)浓度为0~0.196 7 mg/ml时,浓度与吸光度呈现良好的线性关系(r=0.999 8);平均回收率为98.83%,RSD为1.60%;厚朴叶多糖铁(Ⅲ)复合物中铁(Ⅲ)含量为31.42%。[结论]该方法简便迅捷、可靠,可用于厚朴叶多糖铁复合物中铁的含量测定。
[Objective] To determine the Fe(Ⅲ) content in polysaccharide-Fe(Ⅲ) complex of CORTEX MAGNOLIAE OFFICINALIS leaves.[Method] Polysaccharide was extracted from the leaves of CORTEX MAGNOLIAE OFFICINALIS.Under alkaline condition,polysaccharide-Fe(Ⅲ) complex was formed.And the content of Fe(Ⅲ) was determined by UV spectrophotometry.[Result] when the Fe(Ⅲ) content was between 0 and 0.196 7 mg/ml,Absorbance and concentration showed good linear relationship(r=0.999 8);the average recovery rate was 98.83% and RSD was 1.60%;Fe(Ⅲ) content in polysaccharide-Fe(Ⅲ) complex of CORTEX MAGNOLIAE OFFICINALIS leaves was 31.42%.[Conclusion] This method was rapid and reliable and could be used for the Fe(Ⅲ) content in polysaccharide-Fe(Ⅲ) complex of CORTEX MAGNOLIAE OFFICINALIS leaves.
出处
《安徽农业科学》
CAS
2012年第2期791-791,895,共2页
Journal of Anhui Agricultural Sciences
基金
陕西理工学院2011年大学生创新试验项目(UIRP1131)
关键词
厚朴叶多糖铁(Ⅲ)复合物
铁含量
分光光度法
Polysaccharide - Fe (llI) complex
CORTEX MAGNOLIAE OFFICINALtS leaves
Fe (111) content
Spectrophotometry