期刊文献+

基于NIM系统的多道脉冲幅度采集卡设计 被引量:1

Design of Multi-channel Pulse Amplitude Acquisition Card based on NIM System
下载PDF
导出
摘要 比较了计算机多道脉冲幅度分析系统与NIM(Nuclear I nstrument Module)多道脉冲幅度分析系统各自的特点,并介绍了后者的构架及其工作原理。对峰值展宽电路进行了功能分析和指标测试,并用NIM多道脉冲幅度采集卡进行了实际数据获取,从测得数据绘制出了脉冲幅度谱,其半高宽约为0.075%。在经过长达200多个小时的运行测试中,由该多道脉冲幅度采集卡与上位PC机组成的NIM数据获取系统工作稳定,已能初步满足小规模多参数数据获取系统的要求。 It mainly analyzed the characteristics of multi-channel pulse amplitude acquisition analysis system based on the computer and Nuclear Instrument Module(NIM) standards respectively.The latter architecture was introduced,and its working principle was described.After the function analysis and indicators test for the peak stretch circuit,stretched waveforms were given with the AFG3252 as the pulse generator.According to the results of the measured data processing,the pulse amplitude spectrum was drawn out,and its FWHM(Full Width at Half Maximum) was about 0.075%.After running for more than 200 hours,it has been proved that the NIM data acquisition system composed by the multi-channel pulse amplitude acquisition card and the host PC was stable and it can be met the requirements of small-scale multi-parameter data acquisition systems preliminarily.
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2011年第11期1250-1254,共5页 Nuclear Electronics & Detection Technology
基金 HIRFL物理实验平台改造项目基金资助课题(0407060WHO)
关键词 NIM标准 核物理实验 数据获取系统 多道脉冲幅度分析 NIM standard nuclear physics experiments data acquisition system multi-channel pulse amplitude analysis
  • 相关文献

参考文献8

  • 1南钢洋,王彦瑜,张建川,乔卫民.核物理实验中模数转换器选型及其供电方案[J].强激光与粒子束,2011,23(2):471-474. 被引量:4
  • 2敖奇,魏义祥,文向阳.基于DSP的数字化多道脉冲幅度分析器设计[J].核技术,2007,30(6):532-536. 被引量:20
  • 3P. Y. Chang, H.P. Chou. A High Precision Peak Detect Sample and Hold Circuit [ C ]. IEEE J. 2006 IEEE Nuclear Science Symposium Conference Record, N14 - 57:329 - 331.
  • 4Paolo Walter Cattaneo. A technique based on pulse shape comparison for linearizing compressed signals [J]. Nuclear Instruments& Methods In Physics Research A, 2002,481:529-537.
  • 5Mtera Corporation. Cyclone III Handbook [ Z ]. USA : Mtera Corporation, 2008.
  • 6M. W. Kruiskamp,D. M. W. Leenaerts. A CMOS peak detect sample and hold circuit [ J]. IEEE Trans. Nucl. Sci. ,1994,41:295-298.
  • 7Gianluigi De Geronimo, Paul O' Connor. Analog CMOS peak detect and hold circuits [J].Nuclear Instruments and Methods in Physics Research A, 2002, 484 : 552 - 554.
  • 8Wang, Ya,Zhu, Junehao. Design of high speed data acquisition system based on FPGA and DSP[C]. 2010 International Conference on Artificial Intelligence and Education, ICAIE 2010 : 132 - 135.

二级参考文献11

  • 1[1]Sim(o)es J B,Correia C M B A.Nucl Instr Meth in Phys Res,1999,A422:405-410
  • 2[3]14-Bit,40 MSPS/65 MSPS A/D Converter AD9244.http://www.analog.com/UploadedFiles/Data_Sheets/AD9 244.pdf
  • 3[4]Cardoso J M,Sim(o)es J B,Correia C M B A.Nucl Instr Meth in Phys Res,2004,A522:487-494
  • 4Texas Instruments Corporation. ADS8472 datasheet[K]. Dallas: Texas Instruments Corporation, 2006.
  • 5Promitzer. 12 bit low power fully differential switched capacitor nonealibrating successive approximation ADC with 1 MS/s[J]. IEEE J Solid-State Circuits, 2001, 36(7): 1138-1143.
  • 6Cattaneo P W. A technique based on pulse shape comparison for linearizing compressed signals[J]. Nucl Instrum Meth in Phys Res A, 2002, 481:529-537.
  • 7Altera Corporation. Cyclone Ⅲ handbook[K]. San Jose: Altera Corporation, 2008.
  • 8Kruiskamp M W, Leenaerts D M W. A CMOS peak detect sample and hold circuit[J]. IEEE Trans on Nucl Sci, 1994, 41:295-298.
  • 9Linear Technology Corporation. LP3965 datasheet[K]. Denver: Linear Technology Corporation, 2005.
  • 10Linear Technology Corporation. LTC3026 datasheet[K]. Denver: Linear Technology Corporation, 2006.

共引文献22

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部