期刊文献+

温度对生物活性炭反应器净水效能的影响研究 被引量:2

The Effect Study of Temperature on Water Purification Performance of Biological Activated Carbon reactor
下载PDF
导出
摘要 为考察温度变化对生物活性炭反应器净水效能的影响,分别研究了在5-18℃和19-26℃两个温度范围内反应器对高锰酸盐指数、硝态氮、浊度及UV254的去除情况。结果表明:单级生物活性炭反应器对高锰酸盐指数平均值为4.51 mg/L的原水净化能力有限,但常温条件下的效果明显优于低温条件(高锰酸盐指数去除率分别为15.90%和4.38%)。另外,硝态氮的去除也受到低温因素的影响。浊度和UV254在不同温度条件下的去除率没有明显的变化,且UV254随温度的变化表现出明显的滞后性。因此,利用生物活性炭净水装置降低水中高锰酸盐指数和硝态氮时,应避免运行温度降低。在5℃-26℃范围内以降低浊度和UV254为处理目的运行中温度的变化不会明显影响其去除效果。 This experiment investigated the removal of permanganate index, UV254, nitrate nitrogen and turbidi- ty by the biological activated charcoal(BAC) reactor in the temperature of 4 -18 ℃ and 19 to 26 ℃. The result showed that the permanganate index removal ability of BAC was limited which averages were 4.51 mg/L. Per- manganate index removal at common temperatures was better than low temperatures (normal temperaturel5. 90% ,low temperature 4.38% ). The removal of nitrate nitrogen was also influenced by temperature. Removal of turbidity and UV254 under different stage did not show significant changes, but UV show hysteresis to low temperature effect. Therefore, the lower operating temperature should be avoided to reduce nitrate and perman- ganate index of water using biological activated carbon water purification devices. There is no effective transfor- ming of turbidity and UV254 removal rate temperature chan^ed from 5 ℃ to 26 ℃.
出处 《东北电力大学学报》 2011年第5期151-154,共4页 Journal of Northeast Electric Power University
关键词 生物活性炭 硝态氮 浊度 UV254 温度 高锰酸盐指数 BAC Nitrate nitrogen Turbidity UV254 Temperature Permanganate index
  • 相关文献

参考文献2

二级参考文献40

  • 1胡军,周集体,张爱丽,孙丽颖,杨松.光催化—臭氧联用技术协同处理硝基苯废水[J].化工环保,2004,24(z1):192-195. 被引量:17
  • 2赵苏,杨合,孙晓巍.高级氧化技术机理及在水处理中的应用进展[J].能源环境保护,2004,18(3):5-8. 被引量:34
  • 3张晖,程江,杨卓如,陈焕钦.O_3/UV法降解水中对硝基酚[J].环境化学,1996,15(4):313-319. 被引量:17
  • 4洪蔚.利用微臭氧气泡处理污水[J].化工环保,2001,21(5):310-310.
  • 5王琳 王宝贞.饮用水深度处理技术[M].北京:化学工业出版社,2001..
  • 6Amy G L, Sierka R A, Bedessem J, et al. Molecular size distribution of dissolved organic matter [ J ]. AWWA,1992,84(6) :67 - 75.
  • 7Chadik P A,Amy G L. Molecular weight effects on THM control by coagulation and adsorption [ J ]. E E, 1987,113(6): 1234 - 1248.
  • 8Akira Yuasa, Fusheng Li, Yoshihiko Matsui. Characteristics of competitive adsorption of aquatic humic substances onto activated carbon[J]. Wat Sci Tech, 1997,36(12):231 - 238.
  • 9汪大晕.水处理新技术及工程设计[M].北京:化学工业出版社,2001..
  • 10Bdlfahdel H, Ratek A, QuedermiA, et al. Remove of Colour and Organic Matters in Industrial Phosphiric Acid by Ozone Effect on Activated Carbon Treatment [ J]. Proceedings of the 21th World Congress of the International Ozone Association, 1995,1(2) :501 -508.

共引文献69

同被引文献43

  • 1任芝军,马军,曹晓春.生物活性炭强化过滤工艺影响因素的研究[J].现代化工,2006,26(z1):201-203. 被引量:4
  • 2LIAO Xiaobin, CHEN Chao, WANG Zhao, et al. Changes of biomass and bacterial communities in biological activated carbon filters for drinking water treatment[ J ]. Process Biochemistry,2013, 48(2) :312-316.
  • 3GIBERT O, LEFEVRE B, FERNANDEZ M, et al. Characterising blofilm development on granular activated carbon used for drinking water production[ J ]. Water Research ,2013,47 (3) : 1101-1110.
  • 4LOU Jiechun, YANG Chihyuan, CHANG Chejung, et al. Analysis and removal of assimilable organic carbon (AOC) from treateddrinking water using a biological activated carbon filter system [ J ]. Journal of Environmental Chemical Engineering ,2014,2 ( 3 ) : 1684- 1690.
  • 5VELTEN S, BOLLER M, KOSTER O, et al. Development of biomass in a drinking water granular active carbon (GAC) filter [ J]. Water Research ,2011,45 (19) :6347-6354.
  • 6SIMPSON D R. Biofilm processes in biologically active carbon water purification[J]. Water Research,2008,42(12) :2839-2848.
  • 7LI Zongtian, DVORAK B, XU Li. Removing 17/3- estradiol from drinking water in a biologically active carbon (BAC) reactor modified from a granular activated carbon ( GAC ) reactor [ J ]. Water Research ,2012,46 ( 9 ) :2828-2836.
  • 8VELTEN S, HAMMES F, BOLLER M, et al, Rapid and direct estimation of active biomass on granular activated carbon through adenosine tri-phosphate ( ATP ) determination [ J ]. Water Research, 2007,41 ( 9 ) : 1973-1983.
  • 9HAMMES F, BERNEY M, WANG Y, et al. Flow-cytometric total bacterial cell counts as a descriptive microbiological parameter for drinking water treatment processes [ J ]. Water Research, 2008,41 (1/2) :269-277.
  • 10YAPSAKLI K, MERTOGLU B, CECEN F. Identification of nitrifiers and nitrification performance in drinking water biological activated carbon (BAC) filtration [ J ]. Process Biochemistry, 2010,45 ( 9 ) : 1543-1549.

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部