目的:分析常用新生儿听力筛查各方法影响因素,提出假阳性对策,提高筛查准确率。方法:采用GN Otomet-rics公司的ACCUSCREEN手持式耳声发射(OAE)和自动听性脑干反应(AABR)筛查仪,对出生3~7 d的4 115例新生儿进行筛查,依据筛查结果作出分析总结并制定出假阳性对策。结果:针对不同听力筛查方法的筛查结果制定的假阳性对策有效地降低了假阳性率。结论:根据听力筛查方法筛查特点采取合理的措施,能有效降低假阳性率,减轻家长的心理及经济负担。
Objective To analyze the influence factors for the neonate hearing screening and put forward the measures for false positive result,so as to enhance the accuracy of the screening.Methods 4,115 neonates born in 3 to 7 days were screened with ACCUSCREEN handhold OAE AABR screener,and the results were analyzed and the measures for false positive result were put forward.Results The false positive rate from different screening methods were reduced greatly.Conclusion Taking reasonable measures according to characteristics of each screening manner respectively can effectively reduce the false-positive rate and relieve the psychological and financial burden of the parents.