摘要 以浸入沉积的方法在硅纳米线上修饰了金纳米颗粒,并通过电子扫描显微镜(SEM)和X射线荧光分析(XRF)对金纳米粒子修饰的硅纳米线电极表面形貌进行了表征.以修饰后的硅纳米线电极作为工作电极,采用阳极溶出法检测水中痕量铅和铜,考察pH值、富集电位和富集时间对溶出峰的影响,优化出最佳实验条件.在优化的实验条件下,铅Pb2+和铜Cu2+的灵敏度分别为0.649μA/(μg.L-1)和0.177μA/(μg.L-1).检测极限达到0.26μg.L-1和0.67μg.L-1.峰电流与离子浓度在质量浓度25~200μg.L-1的范围内形成良好的线性关系. A novel gold nanoparticles modified silicon nanowires(Au/SiNWs) electrode for anodic stripping analysis of lead(Pb2+) and copper(Cu2+) under the optimum conditions is described in this paper.Gold nanoparticles has been prepared by immersion plating and grafted to silicon nanowires,the morphology of Au/SiNWs electrode is characterized by scanning electron microscope(SEM) and X-ray fluorescence analysis(XRF).The results indicates that the modified electrode displays the excellent linear behavior in the examined concentration(from 25 to 200 μg·L-1).Pb2+ and Cu2+ in 0.1 mol·L-1 HAc-NaAc can be detected with the sensitivity of 0.649 μA/(μg·L-1) and 0.177 μA/(μg·L-1) respectively.The corresponding detection limits are 0.26 μg·L-1 and 0.67 μg·L-1.
出处 《南通大学学报(自然科学版)》 CAS 2011年第4期31-36,共6页 Journal of Nantong University(Natural Science Edition) 
基金 国家自然科学基金项目(61076070)
关键词 硅纳米线电极 差分脉冲溶出伏安法 金纳米粒子 silicon nanowires electrode differential pulse voltammeter anodic stripping voltammetry gold nanoparticles lead copper
  • 相关文献

参考文献20

  • 1Wang J. Stripping analysis at bismuth electrodes:a review[J]. Electroanalysis, 2005, 17(15/16): 1341-1346.
  • 2Wang J. Real-time electrochemical monitoring:toward green analytical chemistry[J]. Acc Chem Res, 2002, 35 (9) :811-816.
  • 3Tao Bairui, Zhang Jian, Hui Shichao, et al. An amperometric ethanol sensor based on a Pd-Ni/SiNWs electrode [J]. Sens Actuators B, 2009, 142(1) :298-303.
  • 4Hui Shichao, Zhang Jian, Chen Xuejiao, et al. Study of an amperometric glucose sensor based on Pd-Ni/SiNW electrode [J]. Sens Actuators, B, 2011, 155 (2) :592-597.
  • 5Cui Yi, Wei Qingqiao, Park Hongkun. Nanowire nanosensors for highly sensitive and selective detection of biological and chemical species[J]. Science, 2001, 293 (5533) : 1289- 1292.
  • 6Hahm J I, Lieber C M. Direct ultrasensitive electrical detection of DNA and DNA sequence variations using nanowire nanosensors [ J ]. Nano Lett, 2004, 4 ( 1 ) : 51-54.
  • 7Orozco J, Fernandez-Sanchez C, Jimenez-Jorquera C. Underpotential deposition anodic tripping vohammetric detection of copper at gold nanoparticle-modified ultramicro-electrode arrays [J]. Environ Sci Technol, 2008, 42 (13): 4877-4882.
  • 8Huang Jingfang, Lin B T. Application of a nanoporous gold electrode for the sensitive detection of copper via mercury- free anodic stripping voltammetry[J]. Analyst, 2009, 134 ( 11 ) : 2306-2313.
  • 9Uhlig A, Schnakenberg U, Hintsche R. Highly sensitive heavy metal analysis on platinum- and gold-uhramicroelectrode arrays[Jl. Electroanalysis, 1997, 9(2):125-129.
  • 10Wang J, Tian Biaomin. Mercury-free disposable lead sensors based on potentiometric stripping analysis at gold-coated screen-printed electrodes[J]. Anal Chem, 1993, 65 (11): 1529-1532.

二级参考文献1

共引文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部