摘要
叙述了在高层建筑的采暖设计中,中高层建筑与低层用户之间,采暖系统连接是设计人员需要仔细考虑的问题,指出,高低区直连采暖系统更为经济合理,提出,高低区直连系统加压泵扬程的计算公式。
In the design of high-rise building heating,high building and bottom of the heating system connection between users is designer carefully considered problem.Pointed out that high and low region direct-connected is even more reasonable in economy in the paper,and accurate calculation formulas of the heating for high and low pressure pump head region direct-connected system are given.
出处
《能源与节能》
2011年第7期92-93,95,共3页
Energy and Energy Conservation
关键词
供暖
高层建筑
高低区直连
heating
high-rise buildings
high and low region direct-connected