摘要 研究了应用动态反应池-电感耦合等离子体质谱法(DRC-ICP-MS)测定钢铁及合金中硫含量的分析方法。针对硫易受多原子离子干扰的特点,采用四极杆质谱仪的动态反应池技术,以O2为反应气,通过测定m/z为48的32S16 O+克服m/z为32的32S+受到的多原子离子干扰,实现了对S的定量分析。研究了仪器的最佳工作条件,基体Fe和共存离子Ca、Ti的干扰效应;选择了合适的分析同位素,采用标准加入法校正了基体的抑制效应。方法检出限为4.0μg/L。将本方法用于实际样品分析,测定值与其它方法结果和标准物质认定值吻合,加标回收率为99%~104%,相对标准偏差均小于6.0%。 A method for the determination of sufur content in iron,steel and alloys by inductively coupled plasma mass spectrometry with dynamic reaction cell(DRC-ICP-MS) has been studied.Since the sulfur was prone to suffer from polyatomic ions interference,the dynamic reaction cell technique of quadrupole mass spectrometer was adopted to overcome the polyatomic ion interference of 32S+(m/z=32) by measuring the 32S16O+(m/z=48) with O2 as reaction gas,realizing the quantitative analysis of S.The optimal working conditions of instrument,the interference effect of matrix Fe and coexisting ions(Ca and Ti) were investigated.The appropriate isotopes for determination were selected.The inhibition effect of matrix was corrected by standard addition method.The detection limit of method was 4.0 μg/L.This method has been applied to the determination of actual samples,and the results were consistent with the certified values and those obtained by other methods with recoveries of 99 %-104 % and relative standard deviations(RSD) smaller than 6.0 %.
出处 《冶金分析》 CAS CSCD 北大核心 2011年第12期6-10,共5页 Metallurgical Analysis
关键词 电感耦合等离子体质谱法 动态反应池 钢铁 合金 inductively coupled plasma mass spectrometry dynamic reaction cell iron and steel alloy sulfur
  • 相关文献

参考文献8

  • 1鞍钢钢铁研究所,沈阳钢铁研究所.实用冶金分析(Practical Metallurgical Analysis)[M].沈阳:辽宁科学技术出版社,1989.240.
  • 2蒋启翠.高频燃烧-红外吸收法测定钢铁中微量碳硫[J].冶金分析,2005,25(4):95-96. 被引量:25
  • 3GB/T223.67-2008钢铁及合金硫含量的测定次甲基蓝分光光度法[S].
  • 4GB/T223.68-1997钢铁及合金化学分析方法管式炉内燃烧后碘酸钾滴定法测定硫含量[S].
  • 5GB/T 4336-2002 碳素钢和中低合金钢火花源原子发射光谱分析方法(常规法)[S].
  • 6兰宇卫,陆建平,章张法,黄元球,汤艳荣.微波消解-吸附柱分离-离子色谱法测定钢样中微量硫[J].冶金分析,2008,28(1):24-26. 被引量:9
  • 7C F Yeh,S J Jiang,T S Hsi. Determination of sulfur- containing amino acids by capillary electrophoresis dynamic reaction cell inductively coupled plasma mass spectrometry[J]. Anal, Chim. Acta, 2004,502 : 57-63.
  • 8李娜 刘养勤 朱丽霞 等.高频燃烧红外吸收法测定X80管线钢中微量碳硫.冶金分析,2008,28(2):986-988.

二级参考文献5

共引文献44

同被引文献183

引证文献10

二级引证文献81

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部