摘要 Hilbert transformation and improved ellipse localization method is applied in ultrasonic transducer array tomography to detect defect of metal plate.By combining the improved ellipse localization method and time-reversal method,the new ultrasonic tomography algorithm employs smooth Hilbert envelope instead of discrete amplitude to reconstruct defect image.An ultrasonic tomography system with six transducers is built to evaluate the effectiveness of the new ultrasonic tomography algorithm.The S0 mode Lamb wave is excited on special condition,and the mode of received signal is identified by Vigner-Wille distribution.The gray value of image area is defined by envelope of the reflected S0 mode Lamb wave signal from defect boundary.Defect image can be reconstructed by summing gray value of all pixels in the image area.The experimentally reconstructed defect image shows that the new tomography algorithm based on Hilbert transformation is efficient for defect detection in metal plate. Hilbert transformation and improved ellipse localization method is applied in ultrasonic transducer array tomography to detect defect of metal plate.By combining the improved ellipse localization method and time-reversal method,the new ultrasonic tomography algorithm employs smooth Hilbert envelope instead of discrete amplitude to reconstruct defect image.An ultrasonic tomography system with six transducers is built to evaluate the effectiveness of the new ultrasonic tomography algorithm.The S0 mode Lamb wave is excited on special condition,and the mode of received signal is identified by Vigner-Wille distribution.The gray value of image area is defined by envelope of the reflected S0 mode Lamb wave signal from defect boundary.Defect image can be reconstructed by summing gray value of all pixels in the image area.The experimentally reconstructed defect image shows that the new tomography algorithm based on Hilbert transformation is efficient for defect detection in metal plate.
出处 《Journal of Beijing Institute of Technology》 EI CAS 2011年第4期514-519,共6页 北京理工大学学报(英文版)
基金 Supported by the National Natural Science Foundation of China(50975028) "111"Project of China(B08043)
关键词 Lamb wave transducer array Hilbert transformation TOMOGRAPHY Lamb wave transducer array Hilbert transformation tomography
  • 相关文献

参考文献11

  • 1Su Zhongqing,Ye Ling,Lu Ye.Guided Lamb waves for identification of damage in composite structures:A review[J] Journal of Sound and Vibration,2006,295(3-5):753-780.
  • 2Toyama N,Noda J,Okabe T Quantitative damage detection in cross-ply laminates using Lamb wave method[J] Composites Science and Technology,2003,63(10):1473-1479.
  • 3Xu Chunguang,Rose J L.Defect sizing of plate-like structure using Lamb waves,QNDE conference proceedings[R].Chicago:American Institute of Physics,2008.
  • 4Malyarenko E V,Mark Hinders.Fan beam and double crosshole Lamb wave tomography for mapping flaws in aging aircraft structures[J].J Acoust Soc Am,2000,108(4):1631-1639.
  • 5Michaels J E,Michaels T E.Guided wave signal processing and image fusion for in-situ damage localization in plates[J].Wave Motion,2007,44(6):482-492.
  • 6Hay T R,Royer R L.A comparison of embedded sensor Lamb wave ultrasonic tomography approaches for material loss detection[J].Smart Mater Struct,2006,15(4):946-951.
  • 7Jansen D P,Hutchins D A,Mottram J T.Lamb wave tomography of advanced composite laminates containing damage[J].J Acoust Soc Am,1994,32(4):83-89.
  • 8Rose J L.Ultrasonic waves in solid media[M].Cambridge,UK:Cambridge University Press,1999:30-85.
  • 9Mirahmadi S J,Honarvar F,Gopalakrishnan S,et al.Application of signal processing techniques to ultrasonic testing of plates by S0 Lamb wave mode[J].NDT&E International,2011,44 (1):131137.
  • 10Jie Zhang,Bruce W D,Wilcox P D,et al.Defect detection using ultrasonic arrays:The multi-mode total focusing method[J].NDT&E International,2010,43(2):123-133.