期刊文献+

胚胎移植后发现胚胎遗漏补插管移植27例分析

原文传递
导出
摘要 胚胎移植是体外受精-胚胎移植(IVF-ET)过程中的关键步骤。临床上约80%的IVF患者可达到ET阶段,但是妊娠率却远远小于80%,改进移植过程,确保移植的有效性是提高妊娠率的重要途径之一[1]。为确保移植的有效性,我中心常规在移植手术后将移植管的内外管均用培养液涮洗,在显微镜下观察有无胚胎遗漏,并对遗漏的胚胎进行补插管移植,获得了较好的妊娠率,现报告如下。
出处 《中国优生与遗传杂志》 2011年第12期109-110,共2页 Chinese Journal of Birth Health & Heredity
  • 相关文献

参考文献8

  • 1李红,邢福祺,全松.胚胎移植距子宫腔基底距离与妊娠率之间的关系[J].南方医科大学学报,2007,27(3):380-381. 被引量:5
  • 2Alikani M, Calderon G, Tomkin G, et al. Cleavage anomalies in early human embryos and survival after prolonged culture in - vitro [ J ]. Human Reprod, 2000,12:2634 -43.
  • 3Lee HC, Seifer DB, Shelden RM. Impact of retained embryos on the outcome of assisted reproductive technologies[J]. Fertil Steril,200.4, 82(2):33 4 -7.
  • 4Spandoffer SD, Goldstein J, Navarro J, et al. Difficultembryo transfer has a negative impact on the outcome of invitro fertilization [ J ]. Fertil Steril, 2003,79 (3): 65 4 - 5.
  • 5Spandorfer SD, GoldsteinJ, Navarro J, et al. Difficult embryo transfer has a negative impact on the outcome of in vitro fertilization [ J ]. Fertil Steril, 2003,79 3:654 -655.
  • 6魏兆莲,曹云霞,丛林,周平,李芬,章志国,赵济华,张文香.胚胎移植技术对体外受精-胚胎移植结局的影响[J].生殖医学杂志,2006,15(3):175-178. 被引量:2
  • 7Mirkin S, Jone EL, Mayer JF, et al. Impact of transabdominal ultrasound guidance onperformance and outcome of trancervical uterine embryo trancefer[ J]. J Assist Reprod Genet, 2003,20: 318 - 22.
  • 8Mansour RT, Aboulghar MA. Opitimizing the embryo transfer technique[ J]. Human Reprod, 2002,17:1149 - 53.

二级参考文献18

  • 1Spandorfer SD,Goldstein J,Navarro J,et al.Difficult embryo transfer has a negative impact on the outcome of in vitro fertilization[J].Fertil Steril,2003,79 (3):654-655.
  • 2Sallam HN,Agameya AF,Rahman AF,et al.Impact of technical difficulties,choice of catheter,and the presence of blood on the success of embryo transfer-experience from a single provider[J].J Assist Reprod Genet,2003,20(4):135-141.
  • 3vanWeering HG,Schats R,McDonnel J,et al.The impact of the embryo transfer catheter on the pregnancy rate in IVF[J].Hum Reprod,2002,17(3):666-670.
  • 4Tomas C,Tikkina K,Tuomivaaral L,et al.The degree of difficulty of embryo transfer is an independent factor for predicting pregnancy[J].Hum Reprod,2002,17 (10):2032-2035.
  • 5Tur-Kaspa I,Yuval Y,Bider D,et al.Difficult or repeated sequential embryo transfers do not adversely affect in-vitro fertilization pregnancy rates or outcome[J].Hum Reprod,1998,13 (12):2452-2455.
  • 6Goudas VT,Hammitt DG,Damario MA,et al.Blood on the embryo transfer catheter is associated with decreased rates of embryo implantation and clinical pregnancy with the use of in vitro fertilization-embryo transfer[J].Fertil Steril,1998,78(5):878-882.
  • 7Pope CS,Cook EK,Arny M,et al.Influence of embryo transfer depth on in vitro fertilization and embryo transfer outcomes[J].Fertil Steril,2004,81(1):51-58.
  • 8van de Pas MM,Weima S,Looman CW,et al.The use of fixed distance embryo transfer after IVF/ICSI equalizes the success rates among physicians[J].Hum Reprod,2003,81(4):774-780.
  • 9Pope CS,Cook E,Amy M,et al.Influence of embryo transfer depth on in vitro fertilization and embryo transfer outcomes[J].Fertil Steril,2004,81(1):51-8.
  • 10Coroleu B,Carreras O,Veiga A.Embryo transfer under ultrasound guidance improves pregnancy rates after in-vitro fertilization[J].Hum Reprod,2000,15:616-20.

共引文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部