摘要 本文基于经典的线源理论和圆柱源理论,求解了土壤源热泵地下换热器的各项热阻。结合热阻概念,建立热平衡方程求解了单位深度换热量。分析了系统运行时间、管内水流速、回填材料导热系数、冬夏季进口水温和岩土类型对热阻和单位深度换热量的影响,为地源热泵系统的优化设计提供参考。 The thermal resistance of ground heat exchanger is calculated according to linear source theory and cylindrical source theory. The heat exchange rate per depth of GHE is calculated by thermal resistance of GHE and thermal balance equation. The effect of running time, flow rate in the pipe, thermal conductivity of grout, inlet temperature and soil type to thermal resistance and heat exchange rate per depth of GHE is analyzed. The results are to provide some guidance for the design of GSHP system
作者 刘俊
出处 《建筑热能通风空调》 2011年第6期75-79,共5页 Building Energy & Environment
关键词 土壤源热泵 地下换热器 线源理论 圆柱源理论 热阻 单位深度换热量 GSHP, ground heat exchanger, linear source theory, cylindrical source theory, thermal resistance, heatexchange rate per depth
  • 相关文献

参考文献15

  • 1P Roth, A Georgiev, A Busso, et al. First in situ determination of ground and borehole thermal properties in Latin America [J]. Ren -ewable Energy, 2004, 29(12): 1947-1963.
  • 2B Sanner, G Hellstrrn, J Spitler, et al. Thermal response test-current status and world-wide application [A]. In: Proceedings of World Geothermal Congress [C]. Antalya (Turkey): 2005.
  • 3Georgios Florides, Soteris Kalogirou. First in situ determination of the thermal performance of a U-pipe borehole heat exchanger, in Cyprus[J]. Applied Thermal Engineering, 2008, 28(2): 157-163.
  • 4魏加项,唐志伟,马重芳,张宏宇,刘文学.地源热泵地下换热系统的实验研究[J].工程热物理学报,2007,28(1):146-148. 被引量:3
  • 5张银安,李斌,陈九法,郁云涛,周培海.竖直U形地埋管换热器换热性能测试与分析[J].暖通空调,2007,37(7):72-78. 被引量:11
  • 6Remund C P. Borehole thermal resistance: laboratory and field studies [J]. ASHRAE Transactions, 1999, 105(1): 439-445.
  • 7J Claesson, A Dunand. Heat Extraction fi'om the Ground by Horizontal Pipes: a Mathematical Analysis [M]. Stockholm: Swedish Council for Building Research, 1983.
  • 8Yian Gu, Dennis L O'Neal. Development of an equivalent diameter expression for vertical U-tube used in ground-coupled heat pumps [J]. ASHARE Transactions, 1998, 104:347-355.
  • 9Yian Gu, Dennis L O'Neal. Modeling the effect of backfills on U-tube ground coil performance [J]. ASHRAE Transactions,1998, 104:356-365.
  • 10Bose J E, Parker J D, McQuiston F C. Design/Data Manual for Closed-loop Gground-coupled Heat Pump Systems [M]. Atlanta: ASHRAE, 1985.

二级参考文献9

  • 1中国有色工程设计研究总院.GB 50019-2003 采暖通风与空气调节设计规范[S].北京:中国计划出版社,2004
  • 2Olympia Zogou, Anastassios Stamatelos. Effect of Climatic Conditions on the Design Optimization of Heat Pump Systems for Space Heating and Cooling. Energy Convers, 1998, 39(7): 609-622
  • 3S B Riffat. Innovative Sustainable Technologies and Buildings Developed By the School of the Built Environment. In: A Review, 12th International Heat Transfer Conference. Grenoble, France: 2002. 389-394
  • 4Jitendra B, singh P E, Gustav Foster P E. Ground Source Technology Application for an Indoor Water Park.ASHRAE Transaction: Symposia, 1998. 687-691
  • 5ASHRAE.地源热泵工程技术指南[M].徐伟,路宾,邹瑜,等,译.北京:中国建筑工业出版社,2001
  • 6中国建筑科学研究院.GB 50366-2005 地源热泵系统工程规范[S].北京:中国建筑工业出版社,2005
  • 7王婧,于凤菊,丁良士.土壤源热泵系统的运行参数实验及分析.北京工业大学
  • 8王婧,于凤菊,丁良士.关于大地导热系统的测试.北京工业大学
  • 9康艳兵,马志永.建筑节能领域可再生能源的利用方式[J].中国能源,2002,24(6):37-40. 被引量:22