摘要
对北京地铁各种换乘车站进行分析,着重从换乘形式、运营管理、开通时序等角度,对换乘车站火灾自动报警系统的设置方案进行阐述;借鉴上海、广州的调研结果,通过对北京地铁实际工程方案的对比,得出适合北京地铁换乘车站火灾自动报警系统资源共享的最优建议方案。
This paper analyzes Beijing subway transfer stations from the perspectives of transfer modes, operation management and time sequence of the opening, it elaborates the schemes for setting transfer stations' fire alarrn systems. By referring to the investigation and research results from Shanghai and Guangzhou and through comparing the investigation results with Beijing railway transportation projects, the best option for fire alarm system resource sharing for Beijing subway transfer stations has been obtained.
出处
《都市快轨交通》
2011年第6期64-68,80,共6页
Urban Rapid Rail Transit
关键词
地铁
换乘车站
换乘形式
火灾自动报警系统
资源共享
subway
transfer stations
transfer modes
automatic fire alarm system
resource sharing