摘要 文章主要描述了"天宫一号"目标飞行器研制过程中与检漏相关的内容,包括检漏项目、检漏方法和检漏结果等。重点介绍了氦质谱吸枪检漏、压力变化检漏和氦质谱非真空累积检漏及多种气体分析等多种检漏方法及其适用范围。"天宫一号"的检漏数据验证了应用以上检漏方法可行且有效。 This paper reviews the leak testing in the development of the experimental module of the Tiangong-Ⅰ target spacecraft,including the leak testing items,the leak testing methods and the leak testing results.Stresses are put on the following three methods,namely,the helium mass spectrum with sniffer,the pressure leak testing,and the helium mass spectrum with cumulation in a non-vacuum container.The leak testing results of Tiangong-I's experimental module validate the feasibility and the effectiveness of each method applied in different leak detection items.
出处 《航天器环境工程》 2011年第6期625-627,共3页 Spacecraft Environment Engineering
基金 国家重大科技专项工程
关键词 目标飞行器 实验舱 检漏 氦质谱 target spacecraft experimental module leak detection helium mass spectrum
  • 相关文献

参考文献4

二级参考文献15

  • 1李旺奎,孟扬.吸枪式质谱计检漏法的定量性研究[J].真空,1996,33(4):13-17. 被引量:4
  • 2闫荣鑫,刘平,冯琪,洪晓鹏,师立侠.压降检漏法的影响因素及改进措施[J].中国空间科学技术,2006,26(4):37-41. 被引量:6
  • 3QJ3088-99正压标准漏孔校准方法[S].北京:中国航天标准化研究所,1999.
  • 4中国航天工业总公司.QJ3089-99氦质谱正压检漏方法[S].北京:中国航天标准化研究所,1999.
  • 5国防科学技术工业委员会.GJB/J5366-2005正压漏孔校准规范[S].北京:中国航天标准化研究所,2005.
  • 6阎治平,真空技术,1980年,3期
  • 7冯师颜,误差理论与实验数据处理,1964年
  • 8GJB3756-99.测量不确定度的表示及评定[S].[S].中国人民解放军总装备部,1999..
  • 9费业泰.误差理论与数据处理[M].北京,机械工业出版社,2002..
  • 10钱绍圣.测量不确定度[M].北京:清华大学出版社,2002..