期刊文献+

循环水紫外杀菌效果评价及影响因素研究 被引量:4

Evaluation of bactericidal effects of UV on circulating water and the research on influencing factors
下载PDF
导出
摘要 评价了紫外技术对循环水的杀菌效果、循环水水质对紫外杀菌效果的影响,并考察了运行参数如杀菌时间、紫外剂量对杀菌效果的影响。结果表明:紫外光对循环水中的3种细菌有较好的杀菌效果。当紫外照射时间为2 s,紫外剂量为0.04 J/cm2,循环水中总铁<0.5 mg/L,浊度<10 mg/L时,可使循环水中的异养菌数<1×105 mL-1。 The bactericidal effects of UV technique on circulating water and the impact of circulating water quality on UV bactericidal effects are evaluated. The impact of operation data such as sterilization time,UV dosage on bactericidal effects are investigated. The results show that UV light has comparatively good bactericidal capacity for three kinds of bacteria in circulating water. When the UV irradiation time is 2 s,UV dosage 0.04 J/cm2,total iron in circulating water〈0.5 mg/L,and turbidity〈10 mg/L,the quantity of heterotrophic bacteria is less than 1×105 mL-1.
出处 《工业水处理》 CAS CSCD 北大核心 2012年第1期47-50,共4页 Industrial Water Treatment
关键词 循环水 紫外杀菌 异养菌 circulating water UV disinfect heterotrophic bacteria
  • 相关文献

参考文献2

二级参考文献9

  • 1[1]A Hollaender, B M Duggar. Irradiation of plant viruses and microorganisms with monochromatic light. Ⅲ. Resistance of the Virus of Typical Tobacco Mosaic and Escherichia Coli to Radiation from L 3000 to L 2250.A See Title Proc N A S, 1936,22:19~24
  • 2[2]A M Rauth. The physical state of viral nucleic acid and the sensitivity of viruses to ultraviolet light. Biophysical Journal, 1965, 5:257~273
  • 3[3]W F Powell. Radiosensitivity as an index of herpes simplex virus development. Virology, 1959, 9:1 ~ 19
  • 4[4]K G Linden, G-A Shin, M D Sobsey. Comparison of monchromatic and polychromatic UV light for disinfection efficacy. Proceedings :American Water Works Association Water Quality Technology Conference. Salt Lake City, Utah, American Water Works Association, Denver, Colorado, November 5~9, 2000
  • 5[5]A H Havelaar, C C E Meulemans, W M Pot-Hogeboom, J Koster.Inactivation of bacteriophage MS2 in wastewater effluent with monochromatic and polychromatic ultraviolet light. Wat Res, 1990,24(11):1 387~1 393
  • 6[6]K G Linden, J L Darby. Estimating effective germicidal dose from medium pressure UV lamps. Journal of Environmental Engineering,1997,123(11):1 142~1 149
  • 7[7]H B Wright. Comparison and validation of UV dose calculation for low and medium pressure mercury arc lamps. Wat Environ Res,2000, 7/8
  • 8[8]A Cabaj, R Sommer, W Pribil, T Haider. What means dose in UV disinfection with medium pressure lamps. Ozone Science & Engineering, 2001, 23: 239~ 244
  • 9[9]R Dulbecco. Experiments on photoreactivation of bacteriophages inactivated with ultraviolet radiation. J Bacteriology, 1950, 59: 329~347

共引文献28

同被引文献37

引证文献4

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部