摘要 有树脂 1300 上的 Geniposide 的突破曲线上的不同脉搏参数的脉搏超声的效果被学习。描述吸附过程的集体转移模型被构造。吸附能力和全面集体转移的系数被适合构造集体转移的模型和试验性的数据获得。在一张固定的床上的 Resin1300 上的 Geniposide 的吸附上的脉搏超声的效果被学习并且比较。在面对超声的树脂 1300 上吸附的 Geniposide 的数量当超声不在时是比那低的,但是没有超声,有超声的照耀的集体转移的率比那高。而且,集体转移率被脉搏调整提高。处于学习的条件,吸附平衡常数与增加超声的力量减少,当全面集体转移的系数增加时。与增加脉搏责任比率,吸附平衡常数开始减少,当脉搏责任比率是 0.5 时,到达最小,然后增加。相反,全面集体转移的系数开始增加并且当脉搏比率是 0.5,然后减少时,到达最大值。吸附平衡和集体转移率上的脉搏时期的效果在 28.6 ms 的脉搏时期到达了山峰。 The effects of pulse ultrasound with different pulse parameters on the breakthrough curves of Geniposide on Resin 1300 were studied. The mass transfer model describing the adsorption process was constructed. Adsorption capability and the overall mass-transfer coefficient were obtained by fitting the constructed mass-transfer model and the experimental data. The effects of pulse ultrasound on adsorption of Geniposide on Resin1300 in a fixed bed were studied and compared. Amount of Geniposide adsorbed on Resin 1300 in the presence of ultrasound is lower than that in the absence of ultrasound, but the mass-transfer rate with ultrasonic irradiation is higher than that without ultrasound. Furthermore, mass transfer rate is enhanced by pulse modulation. In the conditions studied, the adsorption equilibrium constant decreases with increasing ultrasonic power, while the overall mass-transfer co-efficient increases. With increasing pulse duty ratio, adsorption equilibrium constant decreases initially, reaches a minimum when pulse duty ratio is 0.5, and then increases. On the contrary, the overall mass-transfer coefficient in-creases initially and reaches a maximum when pulse ratio is 0.5, and then decreases. Effects of pulse period on ad-sorption equilibrium and mass transfer rate reached the peak at pulse period of 28.6 ms.
出处 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2011年第6期1060-1065,共6页 中国化学工程学报(英文版)
基金 Supported by the National lqatural Science Foundation of China (20346003).
关键词 超声脉冲 固定床吸附 树脂吸附 栀子苷 吸附平衡常数 超声波照射 脉冲占空比 实验数据拟合 ultrasound, cavitation, adsorption, breakthrough curve Geniposide
  • 相关文献

参考文献18

  • 1Hamdaoui, O., Naffrechoux, E., Tifouti, L., Petrier, C., "Effects of ultrasound on adsorption-desorption ofp-chlorophenol on granular activated carbon", Ultrason. Sonochem., 10 (2), 109-114 (2003).
  • 2Juang, R.S., Lin, S.H., Cheng, C.H., "Liquid-phase adsorption and desorption of phenol onto activated carbons with ultrasound", UI- trason. Sonochem., 13 (3), 251-260 (2006).
  • 3Hamdaoui, O., Naffrechoux, E., "Adsorption kinetics of 4-chlorophenol onto granular activated carbon in the presence of high fi'equency ul- trasotmd", Ultrason. Sonochem., 16 ( 1 ), 15-22 (2009).
  • 4Li, Z., Li, X.B., Xi, H.X., Hua, B., "Effects of ultrasound on adsorp- tion equilibrium of phenol on polymeric adsorption resin", Chem. Eng. J., 86 (3), 375-379 (2002).
  • 5Bonn, A., Sarbatly, R., Krishnaiah, D., San, EM., Yah, F., "Effect of ultrasound on liquid phase adsorption of azeotropic and non-azeotropic mixture", Catalysis Today, 131 (1-4), 472-476 (2008).
  • 6Milenkovie, D.D., Dasic, P.V., Veljkovie, V.B., "Ultrasound-assisted adsorption of copper(Ⅱ) ions on hazelnut shell activated carbon", Ultrason. Sonoehem., 16 (4), 557-563 (2009).
  • 7Korkut, O., Sayan, E., Lacln, O., Bayrak, B., "Investigation of ad- sorption and ultrasound assisted desorption of lead (Ⅱ) and copper (Ⅱ) on local bentonite: A modelling study", Desalination, 259 (1-3), 243-248 (2010).
  • 8Commenges-Bernole, N., Marguerie, J., "Adsorption of heavy met- als on sonicated activated sludge", Ultrason. Sonochem., 16 (1), 83-87 (2009).
  • 9Ji, J.B., Lu, X.H., Cai, M.Q., Xu, Z.C., "Improvement of leaching process of Geniposide with ultrasound", Ultrason. Sonochem., 13, 455-462 (2006).
  • 10Flint, E.B., Suslick, K.S., "The temperature of cavitation", Science, 253 (5026), 1397-1399 (1991).