期刊文献+

冠脉320CT成像对胸痛患者冠心病的诊断价值 被引量:1

The value of 320CT imaging for coronary heart disease in patients with chest pain
下载PDF
导出
摘要 目的以常规冠脉造影作为冠心病诊断的参考标准,回顾性对比冠脉320CT成像对胸痛患者冠心病诊断的准确性。方法根据冠脉320CT及常规冠脉造影结果,分析320CT对不同狭窄程度的冠脉显示的敏感性、特异性、阳性预测值、阴性预测值、准确率及不同冠脉分支病变的相关性。结果冠脉320CT诊断冠心病的总体敏感性、特异性、阳性预测值、阴性预测值及准确率分别为91%、83%、87%、88%和88%;对不同冠脉分支病变诊断的一致性较高(r>0.70)。结论冠脉320CT诊断冠心病的准确率较高,可胜任胸痛的鉴别诊断和冠心病的筛查,为冠心病的进一步治疗提供准确资料,使冠心病的治疗更具有针对性。 Objective CAG as the reference standard for diagnosis of CHD, retrospectively compared 320CT imaging to the patients with chest pain of diagnostic accuracy of CHD. Methods According to 320CT and CAG results, analysis of 320CT coronary stenosis on different shows sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and the different branches of coronary artery disease associated. Results 320CT diagnosis of CHD overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 91%, 83%, 87%, 88% and 88% respectively, for different branches of coronary artery narrow higher consistency. Conclusion 320CT higher accuracy of diagnosis of CHD, chest pain may be capable of differential diagnosis and screening of CHD, further treatment of CHD to provide accurate information to enable more targeted treatment of CHD.
出处 《中国现代医生》 2012年第2期131-132,共2页 China Modern Doctor
关键词 冠心病 冠脉造影 320CT成像 胸痛 CHD CAG 320CT imaging Diagnosis Chest pain
  • 相关文献

参考文献4

二级参考文献18

  • 1俞高龙,李海兵,陆明华,桑奇潜,王翀妙.多层螺旋CT量化冠状动脉钙化的评价[J].心脏杂志,2004,16(4):335-336. 被引量:7
  • 2肖喜刚,韩雪,王雪红,孙宏亮,王鸿振,牛洪涛.多层螺旋CT冠状动脉成像在冠心病中的临床应用[J].中华放射学杂志,2004,38(9):957-961. 被引量:66
  • 3陈艳,韩萍,梁波,梁惠民,雷子乔,田志梁,冯敢生.16层螺旋CT冠状动脉成像与DSA的对照研究[J].放射学实践,2005,20(3):195-198. 被引量:20
  • 4杜湘珂,朱锡旭,沈复兴,罗德馨.螺旋CT血管造影[J].中华放射学杂志,1995,29(3):202-204. 被引量:51
  • 5Thai WE,Harper RW,Seneviratne S.Dynamic volume 320-slice CT in the assessment of patent ductus arteriosus for percutaneous closure.Heart,2010,96(4):321.
  • 6Dewey M,de Vries H,de Vries L,et al.The present and future of cardiac CT in research and clinical practice:moderated discussion and scientific debate with representatives from the four main vendors.Rofo,2010,182(4):313-321.
  • 7Burgstahler C,Brodoefel H,Schroeder S.Cardiac CT in 2009.Minerva Cardioangiol,2009,57(4):495-509.
  • 8Ropers D,Baum U,Pohle K,et al.Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.Circulation,2003,107(5):664-666.
  • 9Cademartiri F,Nieman K,Mollet N,et al.Non-invasive 16-row spiral multislice computed tomography coronary angiography after one year of experience.Ital Heart J Suppl,2003,4(7):587-593.
  • 10Alessandri N,Di Matteo A,Rondoni G,et al.Heart imaging:the accuracy of the 64-MSCT in the detection of coronary artery disease.Eur Rev Med Pharmacol Sci,2009,13(3):163-171.

共引文献59

同被引文献8

引证文献1

二级引证文献12