摘要
本文建立了水溶性纺织助染剂中12种氯化甲苯化合物的气相色谱-质谱(GC-MS)测定方法。采用超声萃取法,以正己烷为溶剂分两次提取待测物,用DB-17MS为检测色谱柱气质联用法程序升温方式进行测定,外标法定量。结果表明该方法对12种氯化甲苯化合物的回收率为81.9%~105.6%,方法检测限可达9.8~21.6?g/kg。该法检测限低,准确可靠,适用于水溶性纺织助染剂中氯化甲苯化合物的分析监测。
A testing method for determination of twelve chlorinated toluenes in water-soluble textile dyeing auxiliary with GC-MS was established. With ultrasonic-assisted the sample was extracted twice by n-hexane.Then the extract was analyzed with DB-17MS by the temperature programming mode of GC-MS and was tested by external standard method. The results showed that with this method satisfactory recoveries 81.9%~105.6% and method detection limits 9.8~21.6 *g/kg could be obtained. The method features low detection limits and good accuracy, and could be used for handling water-soluble textile dyeing auxiliary samples.
出处
《质量技术监督研究》
2011年第6期9-12,共4页
Quality and Technical Supervision Research
关键词
测试
纺织助染剂
氯化甲苯
气质联用
Determination
Textile auxiliary
Chlorinated toluene
GC-MS