摘要 通过对全变频自动扶梯故障案例的分析,得出PWM逆变器在应用中产生的dv/dt及脉冲电压是损坏电动机绝缘的主要根源的结论。通过实验表明,dv/dt滤波器可降低峰值电压及dv/dt,从而对电动机的线圈起到保护作用,提高电动机的可靠性以及延长电动机的使用寿命。最后,强调dv/dt滤波器在全变频控制系统中对电动机保护的重要性与必要性。 According to the analysis of full variable frequency escalator's accident, this article draws a conclusion that dv/dt and impulse voltage which caused by application of PWM controller inverter is the main cause of damaging motor insulation. Experiments show that dv/dt wave filter reduces peak value voltage and dv/dt result in the protection of motor coil and promote the reliability and longevity of motor. We emphasize the dv/dt wave filter's importance and necessity of protecting motor in full variable frequency control system.
作者 朱乃将
出处 《中国电梯》 2012年第1期37-39,42,共4页 China Elevator
关键词 dv/dt滤波器 电动机保护 峰值电压变频控制系统 dv/dt wave filter motor protection peak value voltage inverter
  • 相关文献

参考文献4

二级参考文献16

  • 1[1]BUSSED F, ERDMAN J M. The effects of PWM voltage source inverters on the mechanical performance of rolling bearings[J]. IEEE Trans Ind Appl, 1997, 33 (Mar/Apr):567-576.
  • 2[2]ERDMAN J M, KERKMAN R J, SCHLEGEL D W, et al.Effect of PWM inverters on AC motor bearing currents and shaft voltages[J]. IEEE Trans Ind Appl, 1996, 32: 250-259.
  • 3[3]MURAI Y, KUBOTA T. Leakage current reduction for a highfrequency carrier inverter feeding an induction motor[J].IEEE Trans Ind Appl, 1992, 28(July/Aug): 858-863.
  • 4[4]OGASAWARA S, AKAGI H. Modeling and damping of high frequency leakage currents in PWM inverterfed ac motor drive systems[J]. IEEE Trans Ind Appl, 1996, 32(5):1 105-1 114.
  • 5[5]JULIAN A L, LIPO T A. Elimination of common mode voltage in three phase sinusoidal power converters [J].IEEE Trans Power Electronics, 1999, 14(5): 982-989.
  • 6[6]CHEN S T. Modeling of motor bearing current in PWM inverter drives [J]. IEEE Trans Ind Aplications, 1996,32(6): 1 365-1 370.
  • 7周长源,电路理论基础(第2版),1996年,313页
  • 8CHEN S T, LIPO A, FITZGERALD D. Source of induction motor bearing currents caused by PEM inverters[J]. IEEE Trans Energy Conversion, 1996, 11(1):25-32.
  • 9MURAI Y, KUBOTA T. Leakage current reduction for a high- frequency carrier inverter feeding an induction motor[J]. IEEE Trans Ind Appl, 1992, 28(4): 858-863.
  • 10TAKAHASHI I, OGATA A. Active EMI Filter for Switching Noise of High Frequency Inverters[A]. Power Conversion Conf[C]. Nagaoka, 1997. 331-334.

共引文献84

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部