摘要 为保证印制电路板产品的正常工作且不影响周围的电磁环境,基于国际电工委员会的CISPR-22标准中CLASS B要求,搭建测试平台,利用10 m电波暗室对印制电路产品进行电场辐射发射测试,得出印制电路板产品的电场辐射波形不符合参考标准的要求。通过对辐射波形的分析研究,利用电磁屏蔽技术对印制电路板进行改进,再次对该板做辐射发射测试,基本达到参考标准的要求。 In order to make the printed circuit board(PCB) product can work normally and do not influence the electromagnetic environment around,an experiment platform has been set up according to the requirements of CISPR-22 CLASS B published by IEC,and PCB product tests were performed with radiation emission in 10 m electric-wave chamber.The figure of radiated electric field was tested but the result didn't satisfy CISPR-22 CLASS B.The PCB was improved by electromagnetic shielding technology according to the analysis and research of radiation figure and tested again.The result is that PCB satisfied the CISPR-22 CLASS B.
出处 《中国测试》 CAS 北大核心 2012年第1期41-43,47,共4页 China Measurement & Test
关键词 电磁兼容 印制电路板 电磁屏蔽 辐射发射 测试 标准 electromagnetic compatibility printed circuit board electromagnetic shielding radiation emission test standard
  • 相关文献

参考文献3

  • 1MontroseML.电磁兼容的印制电路板设计[M].吕英华,译.北京:机械工业出版社,2008.
  • 2IEC. CISPR 22, edition 5.2 [S]. Geneva: IEC Central Office, 2006.
  • 3郑军奇.EMC设计与测试案例分析[M].北京:电子工业出版社,2006:79-83.

共引文献6

同被引文献58

  • 1周胜海,郭淑红.基于低噪声运放的传感器前置放大器设计[J].仪表技术与传感器,2006(9):38-40. 被引量:31
  • 2林春方,杜先彬,郭立.基于I-F变换的弱电流测量仪的研制[J].上海交通大学学报,2006,40(9):1516-1518. 被引量:8
  • 3李少林,王荣福.核医学[M].7版.北京:人民卫生出版社,2008:88.
  • 4Alexander W. Sauter, Hans F. Wehrl, Armin Kolb, et al. Combined PET/MRI: one step further in multi?modality imaging[J]. Trends in Molecular Medicine, 2010, 16 (11) :508 - 515.
  • 5Shao Y, Cherry SR, Farahani K, et al. Simultaneous PET and MR imaging[J]. Phys Med BioI, 1997, 42 (10) : 1965 -1970.
  • 6Habib Zaidi, Alberto Del Guerra. An outlook on fu?ture design of hybrid PET/MRI systems[J]. Med. Phys. ,2011, 38( 10) : 5667 - 5689.
  • 7Brian Casey, Cynthia E. Keen. Mammography, CT, PET/MRI pace Philips RSNA product debuts[EB/ OLJ.[11 - 29 - 2011J. http://www. auntminnie. comlindex. aspx? sec = rca&sub = rsna_2011&pag = dis&itemId =97535.
  • 8Gaspar Delso, Sebastian Furst, BjornJakoby. Per?formance Measurements of the Siemens mMR Integrat?ed Whole - Body PET/MR Scanner[J].J. Nuc1. Med. ,2011, 52( 12) : 1914 - 1922.
  • 9Bieniosek, M. F. ,Olcott, P. D. ,Levin, C. S .. Time resolution performance of an electro - optical - coupled PET detector for time - of - flight PET/MRI[C]. Nu?clear Science Symposium and Medical Imaging Confer?ence (NSS/MIC), IEEE, 2011 :2531 -2533.
  • 10Tom K Lewellen. Recent developments in PET detec?tor technology[J]. Phys Med BioI, 2008, 53 ( 17) : R287 - R317.

引证文献3

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部