期刊文献+

不同扫描方法在CT冠状动脉成像中的应用研究 被引量:4

Research of different scanning methods in the application of CT coronary angiography
下载PDF
导出
摘要 目的:探讨预注射法与对比剂跟踪法在64层螺旋CT冠状动脉成像的应用价值。方法:70例受检者随机分为A、B两组,分别采用预注射法和对比剂跟踪法行64层螺旋CT冠状动脉成像。利用直线相关分析探讨患者年龄与图像质量之间的相关性,并比较两种扫描方法所得图像质量间的差异。结果:两组患者年龄与图像质量之间均存在负相关,rA=-0.4692,rB=-0.6734,P值均<0.05;A组患者图像质量清晰率为94.3%,B组患者图像质量清晰率为85.7%,两者间差异无统计学意义。结论:64层螺旋CT冠状动脉成像对比剂预注射法和跟踪法均能较好显示冠状动脉病变情况,屏气较差的老年患者优先选择预注射法,而屏气良好的青年患者则优先选择对比剂跟踪法。 Objective:To investigate the application value of test bolus and smart prep Rx technique in multi-slice spiral CT coronary angiography.Methods:70 patients were randomly individed into two groups,for group A the test bolus technique was used,while for group B the smart prep Rx technique was used.The relativity between age and image quality was explored by straight line correlation analysis,and the difference of image quality between the two scanning techniques was compared.Results:There was negative correlation between age and image quality,rA=-0.4692,rB=-0.6734,P0.05;The image quality definition was 94.3% in Group A,and 85.7% in Group B.Conclusion:Test bolus and smart prep Rx used in multi-slice spiral CT coronary angiography both can show coronary artery lesions well,but the former is preferable to the elder patients and the latter to the younger patients.
出处 《放射学实践》 北大核心 2011年第12期1312-1314,共3页 Radiologic Practice
关键词 冠状动脉成像 体层摄影术 X线计算机 预注射法 对比剂 Coronary angiography Tomography X-ray computed Test bolus Contrast media
  • 相关文献

参考文献5

二级参考文献14

  • 1刘玉林,陈宪,郑之青,蒋春林,葛鸿惠,付荣.MSCT血管成像中Boluspro技术的应用[J].放射学实践,2004,19(10):756-759. 被引量:6
  • 2赵进委,沈钧康,钱农,蒋国民.MSCT冠状动脉造影的临床应用[J].中国医学影像学杂志,2005,13(1):40-45. 被引量:9
  • 3陈艳,韩萍,梁波,梁惠民,雷子乔,田志梁,冯敢生.16层螺旋CT冠状动脉成像与DSA的对照研究[J].放射学实践,2005,20(3):195-198. 被引量:20
  • 4朱万安,陈亮,王淑清.影响多层螺旋CT心脏成像质量因素的探讨[J].中国医学影像学杂志,2006,14(1):18-20. 被引量:11
  • 5雷子乔,韩萍,田志梁,刘永华,于群,陈艳.16层螺旋CT后处理方法在评价冠状动脉狭窄中的应用价值[J].临床放射学杂志,2006,25(2):126-129. 被引量:10
  • 6Kopp AF,Schroeder S,Kuettner A et al.Coronary arteries:retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the imagine reconstruction window.Radiology,2001,221:683
  • 7Schroeder S,Kopp AF,Baumbach A.Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography.J Am Coll Cardiol,2001,37(5):1 430
  • 8Filippo Cademartiri,Koen Nieman,Aad van der Lugt,et al.Intravenous Contrast Material Administration at 16 Detector Row Helical CT Coronary Angiography:Test Bolus Versus Bolustracking Technique[J].Radiology,2004,233 (2):817-823.
  • 9Kyongtae TB,Filippo Cadcmartiri,Gabriel PK.Test-Bolus Versus Bolus-tracking Techniques for CT Angiographic Timing Drs Cademartiri and Krestin Respond[J].Radiology,2005,236 (1):369-370.
  • 10Christopher Herzog,Selami Dogan,Thomas Diebold,et al.Vogl Multi-Detector Row CT versus Coronary Angiography:Preoperative Evaluation before Totally Endoscopic Coronary Artery Bypass Grafting[J].Radiology,2003,229 (1):200-208.

共引文献4

同被引文献27

  • 1Furushima H, Chinushi M, Okamura KPacing Clin, et al. Effect of dl-sotalol on mortality and recurrence of ventricular tachyarrhythmias: ischemic compared to nonischemic cardiomyopathy[J]. Electrophysiol, 2007, 30 (9):1136-1141.
  • 2Herzog C, Aming-grb M, Zangos S, et al. Multi-detector row CT-coronary angiography: infl- uence of reconstruction technique and heart rate on image quality[J]. Radiology, 2006,238(1):75-86.
  • 3Filippo Cademartiri, Koen Nieman, Aadvander Lugt, et al. Intravenous contrast material administration at 16 detector row helical CT coronary angiography: test bolus versus bolus tracking technique[J].Radiology, 2004,233 (2):817-823.
  • 4Kyongtae TB, Filippo Cademartiri, Gabriel PK. Test-bolus versus bolus-tracking techniques for CT angiograpbic timing drs cademartiri and krestin respond[J]. Radiology, 2005,236(1):369-370.
  • 5Cademartiri F, Mollet NR, Runza G, et al. Diagnostic accuracy of multislice computed tomography coronary angiography is improved at low heart rates[J]. Int J Cardiovasc Imaging. 2006,22(1):101-105.
  • 6Sakai S, Yabuuchi H, Chishaki A, et al. Effect of cardiac function on aortic peak time and peak enhancement during coronary CT angiography[J]. Eur J Radiol. 2010,75(2): 173-177.
  • 7Nakaura T, Awai K, Yanaga Y, et al. Low-dose contrast protocol using the test bolus technique for 64-detector computed tomography coronary angiography[J]. Jpn J Radiol, 2011, 29(7): 457-465.
  • 8Herzog C,Aming-Erb M,Zangos S,et al.Multi-detector row CT-coronary angiography:infl-uence of reconstruction technique and heart rate on image quality.Radiology,2006,238:75-86.
  • 9Cademartiri F,Nieman K,Lugt A,et al.Intravenous contrast material administration at 16 detector row helical CT coronary angiography:test bolus versus bolus-tracking technique.Radiology,2004,233:817-823.
  • 10Kyongtae TB,Cademartiri F,Gabriel PK.Test-bolus versus bolus-tracking techniques for CT angiographic timing drs cademartiri and krestin respond.Radiology,2005,236:369-370.

引证文献4

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部