期刊文献+

流动注射在线氧化荧光分析法测定柳氮磺吡啶

Determination of Sulfasalazine by Flow Injection On-line Oxidizing Fluorophotometric Method
下载PDF
导出
摘要 研究了硫酸介质中,高锰酸钾氧化柳氮磺吡啶(SASP)体系的荧光特性,结合流动注射进样技术,建立了流动注射在线氧化荧光分析测定SASP的新方法。SASP本身不发荧光,但在硫酸介质中与高锰酸钾反应后可产生1种有强荧光的产物(λex=301 nm,λem=366 nm)。在优化条件下,SASP的质量浓度在1.2×10-5~2.0×10-3 g/L范围内与相对荧光强度呈良好线性,相关系数为0.999 6。方法的检出限为3.0×10-6 g/L,对1.2×10-4 g/L的SASP标准溶液平行测定11次的相对标准偏差为0.6%。该法简单、快速、灵敏度高、选择性好,可用于药物制剂中SASP含量的直接分析。 The fluorescence characteristics of sulfasalazine(SASP) oxidized by potassium permanganate in sulfate acid medium were studied.The result indicated that SASP can react with potassium permanganate in sulfate acid medium to produce a strong fluorescent species(λex=301 nm,λem=366 nm).Based on this phenomenon,a novel on-line oxidizing fluorescent method combined with flow injection technique was established for the determination of SASP.The experimental conditions affecting the fluorescence intensity of the system were investigated.The optimized experimental conditions were as follows: potassium permanganate concentration: 2.0×10-3 mol/L;sulfate acid: 2.0 mol/L;flow rate: 1.2 mL/min;length of mixing tube: 50 cm.Under the optimal experimental conditions,the calibration curves were linear in the range of 1.2×10-5-2.0×10-3 g/L with detection limit of 3.0×10-6 g/L.The relative standard deviation(RSD,n =11) was 0.6% for the determination of 1.2 ×10-4 g/L SASP standard solution.The proposed method had the advantages of simplicity,rapidity,high sensitivity and selectivity,and was successfully applied in the quantitative determination of SASP in enteric-coated tablets with recoveries of 96%-107%.
出处 《分析测试学报》 CAS CSCD 北大核心 2012年第1期62-65,共4页 Journal of Instrumental Analysis
关键词 柳氮磺吡啶 流动注射 在线氧化 荧光分析 sulfasalazine flow injection on-line oxidizing fluorescence analysis
  • 相关文献

参考文献5

二级参考文献20

  • 1曾经泽,黄仁玉.生物药物分析方法的质量控制[J].中国药学杂志,1995,30(11):692-695. 被引量:18
  • 2刘诚,黄俊,肖海燕.肾上腺素的检测进展[J].传感器与微系统,2006,25(11):1-4. 被引量:3
  • 3钟大放.以加权最小二乘法建立生物分析标准曲线的若干问题[J].药物分析杂志,1996,16(5):343-346. 被引量:581
  • 4Burtis C A.Ashwood E R.Tietz Testbook of Clinical Chemistry[M].Philadelphia:Saunders W.B.,1998.1570-1572.
  • 5Goodman L S.Gilman A.The Phanrmacological Basis of the Rapeutics,Ninthed[M].New York:McGraw-Hill,1996.105-112.
  • 6Nagaraja P.Vasantha R A,Sunitha K R.A New Sensitive and Selective Spectrophotometric Method for the Determination of Catechol Derivatives and lts Pharmaceutical Preparations[J].J.Pharmcrceut.Biomed,Anal.,2001,25(3-4):417-424.
  • 7Oosterhuis B.Brunt K,Westerink B H C et al.Electrochemical Detector Flow Cell Based on a Rotating Disk Electrode for Continuous Flow Analysis and High Performance Liquid Chromatography of Catecholamines[J].Anal.Chem.,1980,52(1):203-205.
  • 8Fotopoulou M A,loannou P C.Post-Column Terbium Complexation and Sensitized Fluorescence Detection for the Determination of Norepinephrine,Epinephrine and Dopamine Using High-Performance Liquid Chromatography[J].Anal.Chim.Acta,2002,462(2):179-185.
  • 9Gong J,Lin X.A Glassy Carbon Supported Bilayer Lipid-Like Membrane of 5,5-Ditetradecyl-2-(2-Trimethyl-Ammonioethyl)-1,3-Dioxane Bromide for Electrochemical Sensing of Epinephrine[J].Electrochim.Acta,2004,49(25):4351-4357.
  • 10Seki T.Modified Ethylenediamine Condensation Method and 1ts Application in the Analysis of Catecholamines by Ion-Exchange chromatography[J].J.Chromatography,1978,155(4):415-420.

共引文献1141

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部