恩拉霉素微生物检定法的研究 被引量:11

The Research of Microbiological Assay for the Enramycin
下载PDF
导出
摘要 以枯草芽孢杆菌为检定菌,检定培养基Ⅰ号为试验用培养基,采用双碟法进行恩拉霉素样品测定。通过浸提溶液组成、浸提时间、检定菌浓度考察,优化了检定条件。在此基础上,确立了恩拉霉素浓度的对数值与抑菌圈直径的线性范围,并对所建立的微生物检定法进行准确度、最小检出限等考察。结果表明,采用丙酮浸提液B、浸提恩拉霉素样品80min,恩拉霉素浸提较完全。在检定菌浓度106个/mL的条件下,恩拉霉素浓度在0.56~35.79U/mL之间,其浓度的对数值与相应的抑菌圈直径呈直线相关,相关系数r为0.9960。将建立的恩拉霉素微生物检定法用于恩拉霉素样品测定,回收率为95.90%,相对标准偏差(RSD)为1.95%。本方法可用于含恩拉霉素的样品测定。 Samples containing enramycin were determinated by the double disk method with Bacillus subtilis as test microorganism and antibiotics standardization medium Ⅱ.The determination conditions were optimized through the investigations of extraction solution composition,extraction time and the concentrations of Bacillus subtilis.The linearity of the dose-response relationship was analysised upon it,and the accuracy of the method was checked.The results showed that the optimum deternmination conditions were acidic acetone solution B and 80 min for extraction.The calibration curve was linear within the range from 0.56 to 35.79 U/mL between the logarithm of concentration and the diameter of inhibition zone with the 10^(6) spores /mL of test microorganism constration,the correlation coefficient was 0.9960.The proposed method has been applied to the determination of samples containing enramycin.The recoveries was 95.90%,relative standard deviation(RSD) was 1.95%.This method applies to the detection of enramycin sample.
出处 《中国畜牧兽医》 CAS 北大核心 2012年第1期56-60,共5页 China Animal Husbandry & Veterinary Medicine
基金 兽用抗生素研发及剂形研究开发(技咨037/2011)
关键词 恩拉霉素 浸提 效价测定 微生物检定法 enramycin extraction potency determination microbiological assay
  • 相关文献

参考文献7

二级参考文献39

共引文献63

同被引文献71

引证文献11

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部