期刊文献+

Optimization criteria for the performance of heat and mass transfer in indirect evaporative cooling systems 被引量:8

Optimization criteria for the performance of heat and mass transfer in indirect evaporative cooling systems
原文传递
导出
摘要 The wide application of evaporative cooling techniques in which the optimization criteria form the theoretical basis for improving evaporative cooling performance is essential for energy conservation and emission reduction.Based on exergy analysis and the entransy dissipation-based thermal resistance method,this contribution aims to investigate the effects of flow and area distributions in the optimization of the performance of indirect evaporative cooling systems.We first establish the relationships of exergy efficiency,entransy dissipation-based thermal resistance and cooling capacity of a typical indirect cooling system.Using the prescribed inlet parameters,the heat and mass transfer coefficients and the circulating water mass flow rate,we then numerically validate that when the cooling capacity reaches a maximum,the entransy dissipation-based thermal resistance falls to a minimum while the exergy efficiency is not at an extreme value.The result shows that the entransy dissipation-based thermal resistance,not the exergy efficiency,characterizes the heat transfer performance of an evaporative cooling system,which provides a more suitable method for evaluating and analyzing the indirect cooling system. The wide application of evaporative cooling techniques in which the optimization criteria form the theoretical basis for improving evaporative cooling performance is essential for energy conservation and emission reduction. Based on exergy analysis and the entransy dissipation-based thermal resistance method, this contribution aims to investigate the effects of flow and area distributions in the optimization of the performance of indirect evaporative cooling systems. We first establish the relationships of exergy efficiency, entransy dissipation-based thermal resistance and cooling capacity of a typical indirect cooling system. Using the pre- scribed inlet parameters, the heat and mass transfer coefficients and the circulating water mass flow rate, we then numerically validate that when the cooling capacity reaches a maximum, the entransy dissipation-based thermal resistance fails to a minimum while the exergy efficiency is not at an extreme value. The result shows that the entransy dissipation-based thermal resistance, not the exergy efficiency, characterizes the heat transfer performance of an evaporative cooling system, which provides a more suitable method for evaluating and analyzing the indirect cooling system.
出处 《Chinese Science Bulletin》 SCIE CAS 2012年第6期687-693,共7页
基金 supported by the National Natural Science Foundation of China (51006060)
关键词 蒸发冷却系统 间接蒸发 传质性能 优化准则 传热性能 循环水流量 蒸发冷却技术 冷却性能 indirect evaporative cooling, optimization criteria, entransy dissipation-based thermal resistance, exergy efficiency
  • 相关文献

参考文献6

二级参考文献47

共引文献101

同被引文献134

引证文献8

二级引证文献75

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部