期刊文献+

多普勒超声心动图检测冠心病患者的内皮依赖性血管舒张功能 被引量:3

Clinical Application of Doppler Echocardiography for Assessing Endothelium dependent Vascular Relaxation in Coronary Heart Disease
下载PDF
导出
摘要 目的 利用多普勒超声评价冠心病 (CHD)患者的血管内皮功能。方法 对 3 2例CHD患者和 3 2例正常人肱动脉充气加压及舌下含服硝酸甘油前后血管直径和血流速度变化的检测。结果 CHD患者肱动脉加压前后的血管直径和血流速度变化百分比明显小于正常对照组 ;而舌下含服硝酸甘油前后肱动脉内径及血流速度变化百分比在两组之间无明显差异。结果 CHD患者存在血管内皮功能下降 ,多普勒超声可作为评价血管内皮功能的一种新方法。 Objective To study the vascular endothelial function in the patients with coronary heart disease (CHD).Methods The subjects consisted of 32 CHD patients and 32 matched normal controls. Brachial artery diameter and blood flow velocity were measured with the Doppler ultrasound at basal and at hyperemic condition respectively. Results The increased percentage of the brachial artery diameter and blood flow velocity at hyperemic condition was lower in patients with CHD than that in normal controls. However,there was no significant difference in response to nitroglycerin between the CHD patients and the normal controls. Conclusion Endothelial dysfunction existed in patients with CHD,Doppler ultrasound can be used as a new method for evaluating the function of vascular endothelium. [
出处 《中国医学影像技术》 CSCD 北大核心 2000年第2期118-119,共2页 Chinese Journal of Medical Imaging Technology
关键词 多普勒超声 内皮依赖 舒张 冠心病 Doppler ultrasound Endothelium dependent relaxation Coronary heart disease
  • 相关文献

同被引文献21

  • 1高甬东,吴爱娟,桂鸣.超声测定肱动脉舒张功能对老年高血压患者血管内皮功能障碍的评价[J].中华老年医学杂志,2005,24(2):126-127. 被引量:2
  • 2邓平,赵水平,戴海鹰,黄红光,洪绍彩,吴智鸿.阿托伐他汀对高胆固醇血症兔主动脉环氧合酶2的影响[J].中国动脉硬化杂志,2006,14(2):132-136. 被引量:2
  • 3Harrison D G, Ohara Y. Physiologic consequences of increased vascular oxidant stresses in hypercholesterolemia and atherosclerosis: Implication for impaired vasomotion[J]. Am J Cardiol, 1995,75:75- 81.
  • 4Celermajer D S, Sorensen K E, Gooch V M, et al. Noninvasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis[J]. Lancet, 1992,340:1 111-1 115.
  • 5Nakaki T, Kato R. Beneficial circulatory effect of L-arginine[J]. Japan J Pharmarcol, 1994,66:167-171.
  • 6Zeiher A M, Drexler H, Wollschyger, et al. Modulation of coronary vascular tone in humans., progressive endothelial dysfunction with different early stages of coronary atheroselerosis[J]. Circulation, 1991,83 : 391.
  • 7Nitzan M, Babchenko A, Faib I, et al. Assessment of changes in arterial compliance by Photoplethysmography [C].// The Elecctrical and Electronic Engineers, the 21st IEEE Convention of. Israel, IEEE Press, 2000:351-354.
  • 8Asada H H, Shaltis P, Reisner A, et al. Mobile monitoring with wearable photoplethysmographlc biosensors[J]. Engineering in Medicine and Biology Magazine, 2003,22 (3) : 28-40.
  • 9Kazanavicius E, Gircys R, Vrubliauskas A, et al. Mathematical methods for determing the foot point of the arterial pulse wave and evaluation of proposed methods[J]. Information tech & control, 2005, 34( 1 ) :29-36.
  • 10Guazzi M, Lenatti L, Tumminello G, et al. The behavior of the flow-mediated brachial artery vasodilatation during orthostatic stress in normal man[J]. Acta Physiol Scand,2004,182(4):353- 360.

引证文献3

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部