期刊文献+

Pentacam三维眼前节分析诊断系统在眼前节影像分析中的应用进展 被引量:12

Current progress in the application of Pentacam scheimpflug system in anterior eye segment photography
下载PDF
导出
摘要 Pentacam三维眼前节分析诊断系统是应用旋转scheimpnug成像原理的眼前节测量及分析系统,其通过旋转摄影获取眼前节多重图像,一次成像可获取眼前节的完整信息,具有角膜厚度测量、角膜前后表面地形图测量、三维前房分析和晶状体分析等多种功能。作为一种新的眼前节影像分析系统,Pentacam 可广泛应用于角膜和晶状体屈光手术、圆锥角膜的早期诊断、青光眼早期防治和白内障手术选择等。就Pentacam三维眼前节分析诊断系统在眼前节的应用及特点进行综述。 Pentacam scheimpflug system utilize the principle of Scheimpflug to image the anterior eye segment. It equips with an automatieally rotating Seheimpflug camera to perform a complete measurement of the anterior segment. A preeise analysis of the eorneal thiekness,corneal topography,anterior chamber and crystalline lens are carried out during the operation. These data then provide the basis for a three-dimensional model of the complete anterior segment. The Pentacam scheimpflug system offers a wide range of functions in refractive surgery, keratoconus analysis,glaueoma screening and phaeoemulsification. The newest progression in the application of the Pentacam in anterior ocular segment photography were reviewed.
出处 《中华实验眼科杂志》 CAS CSCD 北大核心 2012年第2期176-179,共4页 Chinese Journal Of Experimental Ophthalmology
关键词 Pentacam三维眼前节分析诊断系统 眼前节 scheimpnug成像 影像检查 Pentacam scheimpflug system Anterior eye segment Scheimpflug photography Image study
  • 相关文献

参考文献31

  • 1Wegener A,Laser-Junga H.Photography of the anterior eye segment according to Scheimpflug' s principle:options and limitations-a review[J].Clin Experiment Ophthalmol,2009,37:144-154.
  • 2Matsuda J,Hieda O,Kinoshita S.Comparison of central corneal thickness measurements by Orbscan Ⅱ and Pentacam after corneal refractive surgery[J].Jpn J Ophthalmol,2008,52:245-249.
  • 3Gordon MO,Beiser JA,Brandt JD,et al.The Ocular Hypertension Treatment Study:baseline factors that predict the onset of primary openangle glaucoma[J].Arch Ophthalmol,2002,120:714-720.
  • 4O' Donnell C,Maldonado-Codina C.Agreement and repeatability of central thickness measurement in normal corneas using ultrasound pachymetry and the OC U LUS Pentacam[J].Cornea,2005,24:920-924.
  • 5Miranda MA,Radhakrishnan H,O' Donnell C.Repeatability of corneal thickness measured using an Oculus Pentacam[J].Optom Vis Sci,2009,86:266-272.
  • 6Chen S,Huang J,Wen D,et al.Measurement of central corneal thickness by high-resolution Scheimpflug imaging,Fourier-domain optical coherence tomography and ultrasound pachymetry[J/OL].Acta Ophthalmol,2010[2010-08-24].http://onlinelibrary.wiley.com/doi/10.1111/j.1755-3768.2010.01947.x/full.
  • 7Al-Mezaine HS,Al-Amro SA,Kangave D,et al.Comparison of central corneal thickness measurements using Pentacam and ultrasonic pachymetry in post-LASIK eyes for myopia[J].Eur J Ophthalmol,2010,20:852-857.
  • 8Bourges JL,Alfonsi N,Laliberte JF,et al.Average 3-dimensional models for the comparison of Orbscan Ⅱ and Pentacam pachymetry maps in normal corneas[J].Ophthalmology,2009,116:2064-2071.
  • 9Doors M,Cruysberg LP,Berendschot TT,et al.Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation[J].Graefe ' s Arch Clin Exp Ophthalmol,2009,247:1139-1146.
  • 10Lackner B,Schmidinger G,Pieh S,et al.Repeatability and reproducibility of central corneal thickness measurement with Pentacam,Orbscan,and ultrasound[J].Optom Vis Sci,2005,82:892-899.

二级参考文献7

  • 1费安裕,林咸平.晶状体异物及白内障摘出联合人工晶状体植入术[J].中国中医眼科杂志,2004,14(3):162-163. 被引量:1
  • 2Hope-Ross M, Mahon GJ, Johnston PB. Ocular sidemsis. Eye, 1993,7:419-425.
  • 3Lee LR, Briner AM. Intralenticular metallic foreign body. Aust N Z J Ophthalmol, 1996,24:361-363.
  • 4Grewal SP, Jain R, Gupta R, et al. Role of scheimpflug imaging in traumatic intralenticular foreign body. Am J Ophthalmol,2006, 142:675-676.
  • 5Lee W, Park SY, Park TK, et al. Mature cataract and lensinduced glaucoma associated with an asymptomatic intralenticular foreign body. J Cataract Refract Surg,2007,33:550-552.
  • 6Kumar A, Kumar V, Dapling RB. Traumatic cataract and intralenticular foreign body. Clin Experiment Ophthalmol, 2005, 33:660-661.
  • 7程瑜,陈彬福,叶纹.眼铁质沉着症诊治分析[J].眼外伤职业眼病杂志,2001,23(2):130-133. 被引量:5

共引文献2

同被引文献110

引证文献12

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部