低剂量与常规剂量对比剂双能量肺灌注图像质量对比分析 被引量:4

Comparative analysis between low-dose and conventional-dose contrast medium of dual energy lung perfusion imaging
下载PDF
导出
摘要 目的:探讨对比剂剂量对双源CT双能量肺灌注成像质量的影响。方法:疑肺动脉栓塞患者行双源CT双能量肺灌注扫描,30例使用低剂量(0.7ml/kg)对比剂,30例使用常规剂量对比剂(1.5ml/kg),注射速率均为4.5ml/s。扫描后同时获得肺动脉CTA及肺灌注图像。测量左、右叶肺动脉干及各肺叶动脉增强后的CT值,对比分析两组间增强后的CT值。判断肺灌注图像质量并分级,比较两组的肺灌注图像质量差异。结果:低剂量组与常规剂量组左、右叶肺动脉干及各肺叶动脉增强后的CT值无明显差异(P>0.05)。肺段及亚段肺动脉图像清晰显示。低剂量组肺灌注图像大部分信号均匀(26/30),常规剂量组肺灌注图像大部分信号均匀(24/30)。常规剂量组上腔静脉、右心房高密度对比剂所致灌注伪影明显多于低剂量组(48:10)。结论:低剂量与常规剂量双能量肺灌注成像的肺动脉图像质量无明显差异,降低对比剂剂量可以减少双能量肺灌注图像的伪影。 Objective:To investigate the effects of low-dose contrast medium on image quality of dual source CT dual energy lung perfusion imaging(DEPI).Methods:Thirty consecutive patients with suspected pulmonary embolism(PE) underwent dual source CT perfusion imaging with low-dose(0.7 ml/kg) contrast medium,another 30 patients with conventional doses of contrast medium(1.5 ml /kg).CT pulmonary angiography(CTPA) and lung perfusion images were acquired at the same time.Injection rates of two groups were 4.5 ml /s.The enhanced CT values of pulmonary artery were measured.The quality and grade of lung perfusion image were determined and comparative analysis was performed between the two groups.Results:There was no significant difference between low-dose group and the conventional dose group in enhanced CT value of pulmonary artery(P0.05).Segment and sub segmental pulmonary were clearly showed.The lung perfusion images were homogeneous signal in majority cases of low-dose group(26/30),but the majority of conventional-dose group were heterogeneous signal(24/30).Conventional-dose group was significantly higher than low-dose group in artifacts due to the high density of contrast medium of superior vena cava and right atrium(48:10).Conclusion:There was no significant difference between low-dose and conventional-dose DEPI in image quality and reduced dose of contrast medium can reduce the artifacts of DEPI.
出处 《医学影像学杂志》 2012年第1期54-57,共4页 Journal of Medical Imaging
关键词 肺栓塞 体层摄影术 X线计算机 双源 对比剂 双能量肺灌注成像 Dual source CT Contrast medium Dual energy lung perfusion imaging
  • 相关文献

参考文献13

  • 1Pontana F,FaivreJB,Remy,et al.Lung perfusion with dual energy multidetector row CT (MDCT):feasibility for the evaluation of acute pulmonary embolism in 117 consecutive patients[J].Acad Radiol,2006,15:1494-1504.
  • 2张龙江,吴新生,赵艳娥,周长圣,柴学,黄伟,卢光明.双源CT双能量肺灌注成像在可疑肺栓塞患者的初步应用[J].临床放射学杂志,2009,28(4):474-478. 被引量:17
  • 3Eun JC,Joon BS,Yu MJ,et al.Dual-energy CT for assessment of the severity of acute pulmonary embolism:pulmonary perfusion defect score compared with CT angiographic obstruction score and right ventricular/left ventricular diameter ratio[J].AJR,2010,194:604-610.
  • 4Sangwaiya MJ,Kalra MK,Sharma A,et al.Dual-energy computed tomographic pulmonary angiography:a pilot study to assess the effect on image quality and diagnostic confidence[J].J Comput Assist Tomogr,2010,34:46-51.
  • 5Rao QA,Newhouse JH.Risk of nephropathy after intravenous administration of contrast material:a critical literatureanalysis[J].Radiology,2006,239:392-397.
  • 6McCullough PA,Wolyn R,Rocher LL,et al.Acute renal failure after coronary intervention:incidence,risk factors,and relationship to mortality[J].Am J Med,1997,103):368-375.
  • 7Katzberg RW,Newhouse JH.Intravenous contrast medium induced nephrotoxicity:is the medical risk really as great as we have come to believe?[J].Radiology,2010,256; 21-28.
  • 8Fink C,Johnson TR,Michaely HJ,et al.Dual-energy CT angiography of the lung in patients with suspected pulmonary embolism:initial results[J].Rofo,2008,180:879-883.
  • 9Thieme SF,Becker CR,Hacker M,et al.Dual energy CT for the assessment of lung perfusion correlation to scintigra phy[J].Eur J Radiol,2008,68:369-374.
  • 10Behrendt FF,Schmidt B,Plumhans C,et al.Image fusion in dual energy computed tomography:effect on contrast enhancement,signal-to-noise ratio and image quality in computed tomography angiography[J].Invest Radiol,2009,44:1-6.

二级参考文献7

共引文献31

同被引文献35

  • 1刘圣.老年人肺栓塞的影像学诊断和介入治疗进展[J].实用老年医学,2013,27(10):799-803. 被引量:3
  • 2刘士远,陈起航,吴宁,等.实用胸部影像诊断学[M].北京:人民军医出版社,2012:717-719.
  • 3Gorgos A, Remy-Jardin M, Duhamel A, et al. Evaluation of pe- ripheral pulmonary arteries at 80 kV and 140 kV: dual-energy computed tomography assessment in 51 patients[J]. J Comput Assist Tomogr, 2009,33 (6) ~ 981 - 986.
  • 4Wittram C. How I do it: CT pulmonary angiography[J] AIR, 2007,188(5) ~ 1255- 1261.
  • 5Remy-Jardin M, Remy J, Deschildre F, et al. Diagnosis of pulmo- nary embolis with spiral CT comparison with pulmonary angiog- raphy and scintigraphy[J]. Radiology, 1996,200(3) : 699.
  • 6Rao Q A, Newhouse J H. Risk of nephropathy after intravenousadministration of contrast material: a critical literature analysis [J]. Radiology, 2006,239 (2) : 392 - 397.
  • 7Katzberg R W, Newhouse J H. Intravenous contrast medium in- duced nephrotoxicity:is the risk reatly as great as we have come to believe.'? [J]. Radiology,2010,256(1) :21-28.
  • 8Leschka S, Stolzmann P, Desbillles L, et al. Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary ste- noses:first experience[J]. Eur Radiol, 2009 ,19 (12 ) : 2896 - 2903.
  • 9De Zordo T,von Lutterotti K,Dejaeo C,et al. Comparison of im- age quality and radiation dose of different pulmonary CTA proto- cols on 128-slice CT: high-pitch dual source CT,dual energy CT and conventional spiral CT[J]. Eur Radiol, 2012,22 (2) : 279 - 286.
  • 10Bauer R W, Schell B, Beeres M, et al. High-pitch dual-source computed tomography pulmonary angiography in freely breath- ing patients[J]. J Thorac Imaging,2012,27(6) :376-381.

引证文献4

二级引证文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部