期刊文献+

国产三件套可膨胀型阴茎假体植入治疗勃起功能障碍 被引量:3

下载PDF
导出
摘要 目的:观察国产三件套可膨胀型阴茎假体对勃起功能障碍(erertile dysfuntion,ED)患者的临床治疗效果。方法:对6例ED患者选择阴茎阴囊交界处切口植入国产三件套可膨胀型阴茎假体。其中动脉粥样硬化患者2例,阴茎海绵体纤维化2例,骨盆骨折后勃起功能障碍2例。结果:6例患者手术均获得成功。术后随访3~40个月,平均12个月。术后3个月所有患者及其配偶均对性生活满意。随访过程未发现机械故障和尿道损伤。结论:国产可膨胀型阴茎假体安全有效,患者满意率高。
出处 《南京医科大学学报(自然科学版)》 CAS CSCD 北大核心 2012年第1期150-152,共3页 Journal of Nanjing Medical University(Natural Sciences)
基金 江苏省"六大人才高峰"项目资助
  • 相关文献

参考文献15

  • 1Hellstrom WJ,Montague DK,Moncada I,et al. Implants, mechanical devices, and vascular surgery for erectile dys- function[J]. J Sex Med,2009,7(1 Pt 2):501-523.
  • 2Henry GD. Historical review of penile prosthesis design and surgical techniques:part 1 of a three-part review se- ries on penile prosthetic surgery [J]. J Sex Med,2009,6 (3):675-681.
  • 3Eid JF. What is new for inflatable penile prostheses?[J]. Curr Opin Urol,2009,19(6) :582-588.
  • 4Lighffoot A J, Rosevear HM,Kreder KJ. Inflatable penile prostheses : an update [J]. Curr Opin Urol,2010,20(6) : 459-464.
  • 5刘继红,张炎,李铮,刘毅东,陈斌.治疗勃起功能障碍的国产可膨胀阴茎假体[J].中国医疗器械杂志,2005,29(4):267-269. 被引量:5
  • 6Dhar NB,Angermeier KW, Montague DK. Long-term me- chanical reliability of AMS 700CX/CXM inflatable penile prosthesis[J]. J Urol,2006,176(6 Pt 1) :2599-2601.
  • 7McKim SE,Carson CC 3rd. AMS 700 inflatable penile prosthesis with InhibiZone [J]. Expert Rev Med Devices, 2010,7(3) :311-317.
  • 8Mansouri MD, Boone TB, Darouiche RO. Comparative as- sessment of antimicrobial activities of antibiotic-treated penile prostheses [ J]. Eur Urol, 2009,56 (6) : 1039-1045.
  • 9Salem EA,Wilson SK, Neeb A, et al. Mechanical reliability of AMS 700 CX improved by parylene coating [J]. J Sex Med, 2009,6(9) : 2615-2620.
  • 10Kim DS,Yang KM,Chung HJ,et al.AMS 700CX/CXM inflatable penile prosthesis has high mechanical reliabili- ty at long-term follow-up [J]. J Sex Med,2010,7 (7): 2602-2607.

二级参考文献17

  • 1李铮,黄翼然,朱选文,朱希宏,王益鑫.国产可膨胀性阴茎假体的研制与临床应用[J].中华男科学杂志,2004,10(12):919-921. 被引量:8
  • 2沈留成,周平,谢亚平,臧美孚,李汉忠,孙晓俊.硅橡胶-银阴茎假体植入治疗阳萎102例报告.[J].临床泌尿外科杂志,1994,9(4):205-206. 被引量:2
  • 3Melman A, et al. The epidemiology and pathophysiology of erectile dysfunction.J Urol. 1999, 161:5-11.
  • 4Montague DK, Lakin MM. Early experience with the controlled girth and length expanding cylinder of the American Medical Systems Ultrex penile prosthesis. J Urol, 1992,148:1444.
  • 5Joseph DB, Bruskewitz RC, Benson RC, et al. Long-term evaluation of the inflatable penile prosthesis. J Urol, 1984, 131:670.
  • 6Wilson SK, Cleves MA, Delk JR. Ultrex cylinders: problems with uncontrolled lengthening (the S-shaped deformity). J Urol, 1996,155:135.
  • 7Scott FB, Bradely WE, Timm GW. Management of erectile impotence: Use of implantable prosthesis. Urology, 1973,2:80.
  • 8Montague DK. Experience with the AMS 700 CXM penile prosthesis. Int J Impot Res, 1990, 2:451-457.
  • 9Woodworth BE, Carson CC, Webster GD. Inflatable penile prosthesis: effect of device modification on functional longevity. Urology, 1991,38:533.
  • 10Nickas ME, Kessler R, Kabalin JM. Long-term experience with controlled expansion cylinders in the AMS 700CXM inflatable penile prosthesis and comparison with earlier versions of the Scott inflatable penile prosthesis. Urology, 1994,44:400.

共引文献32

同被引文献18

引证文献3

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部