期刊文献+

电压检测型地面电气设备漏电保护技术改造 被引量:3

Voltage Detection Ground Electric Installation Leakage Protection Technology Transformation
下载PDF
导出
摘要 煤矿地面电气系统的接地和接零的接线保护方式,与漏电保护装置配合,经实践验证,存在着盲区。为消除安全隐患,对地面三相和单相电气设备漏电保护进行改进,采用电压检测型漏电保护。该漏电保护技术经现场长期实践验证,实现了漏电超过安全电压立即断电的功能,既消除人身触电隐患,又避免漏电保护过于灵敏无法送电,同时还解决了设备正常运行时轻微漏电无法使用漏电保护装置的问题。 The ground and neutral wiring protection ways of coal mine ground electrical system leakage protection device, which problems, the ground three-phase exist blind area by practical proving. In order to eliminate and single phase electrical equipment leakage protection are which adopts voltage detection leakage protection. This leakage coordinates with potential safety being improved, protection technology realizes the function that cuts off immediately when leakage over safety pressure by long-term practical proving. It both eliminates personal electric shock hazard, but also avoids the leakage protection too sensitive to transmit power, while the problem that device can not use when slight leakage during normal operation is also solved.
出处 《煤矿机电》 2012年第1期108-110,共3页 Colliery Mechanical & Electrical Technology
关键词 接地和接零保护 电压检测型漏电保护 ground and neutral protection voltage detection leakage protection condition
  • 相关文献

同被引文献9

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部