摘要 目的比较硬式纤维支气管镜与软式纤维支气管镜经口气管插管的临床应用效果。方法 80例经口气管插管全麻下行腹腔镜手术的ASAⅠ或Ⅱ级患者,随机均分为硬式纤维支气管镜组(S组)和软式纤维支气管镜组(F组)。麻醉前行Mallampati气道评估分级,记录两组在麻醉诱导前、诱导后、气管插管即刻及插管后1、3、5min的SBP、DBP和HR。并记录插管时间和气管插管成功率。结果两组Mallampati气道分级情况差异无统计学意义。两组患者气管插管即刻、插管后1min的SBP、DBP明显高于诱导后,HR明显快于诱导后(P<0.05)。F组患者气管插管即刻的SBP、DBP明显高于S组,HR明显快于S组(P<0.05),插管后1min的HR也明显快于S组(P<0.05)。S组插管时间(47.6±7.9)s,明显短于F组的(61.4±14.7)s(P<0.05)。Mallampati气道评估分级Ⅲ~Ⅳ级患者插管成功率S组为88.89%,明显高于F组的54.54%(P<0.05)。结论硬式纤维支气管镜气管插管成功率高且插管时间短,但插管时血流动力学仍有一定波动,适用于一般患者及气道评估为Ⅲ~Ⅳ级气道的患者。
出处 《临床麻醉学杂志》 CAS CSCD 北大核心 2012年第1期56-57,共2页 Journal of Clinical Anesthesiology
  • 相关文献

参考文献5

二级参考文献18

  • 1Miller C.management of the difficult intubation in closed malpractice claims[J].American Society of Anesthesiologists NEWSLETTER,2000,64(6)13-19.
  • 2Brain AIJ,Verghese C,Strube PJ.The LMA Proseal:A laryngeal mask with an esophageal vent[J].Br J Anaesth 2000,84(5):650-654.
  • 3Davis L,Cook-Sather SD,Schreiner MS.Lighted stylet racheal intubation:A review[J].Anesth Analg,2000,90:745-756.
  • 4Shikani AH.New "seeing"stylet scope and method for the management of the difficult airway[J].Otolaryngol Head Neck Surg,1999,120:113-116.
  • 5Mohanad S,Ryan D,Hanson,et al.Management of the difficult pediatric airway with Shikani Optical Stylet[J].Pediatric Anesthesia,2005,15:342-345.
  • 6Argo F,Cataldo R,Carassiti M,et al.The Seeing Stylet:a new device for tracheal intubation[J].Resucitation,2000,44:177-180.
  • 7Kimura.Use of the fiberoptic stylet scope (Styletscope) reduce the hemodynamic response to intubation in normotensive and hypertensive patients[J].Can J Anesth,2001,48(9):919-923.
  • 8Ahmed AB, Nathanson MH, Gajraj NM. Tracheal intubation through the laryngeal mask airway using a gum elastic bougie: the effect of head position [J]. J Clin Anesth, 2001,13(6):427.
  • 9Evans A, Morris S, Petterson J, et al. A comparison of the Seeing Optical Stylet and the gum elastic bougie in simulated difficult tracheal intubation: a manikin study [J]. Anaesthesia, 2006, 61(5):478.
  • 10Young CF, Rosenblatt WH. Comparison of the Shikani Optical Stylet to direct laryngoscopy for orotracheal intubation by a first year resident [J]. Anesthesiology, 2004, 101 :A605.

共引文献204

同被引文献18

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部