期刊文献+

小型钛板坚固内固定治疗下颌骨骨折98例临床观察 被引量:7

下载PDF
导出
摘要 随着经济的发展,交通事故呈逐年上升趋势,造成颌骨骨折发病率日趋增高。该部位骨折后,严重影响患者颌面外形、语言、咀嚼、吞咽、呼吸甚至视力等[1]。随着生物材料的发展,小型钛板被广泛应用于下颌骨骨折的固定,而颌间结扎等技术逐渐退居到次要地位[2]。
作者 巨利峰
出处 《中国药物与临床》 CAS 2012年第2期218-219,共2页 Chinese Remedies & Clinics
  • 相关文献

参考文献9

二级参考文献39

  • 1温新凤,莫晓东,区跃坚.钛板内固定与颌间固定治疗下颌骨骨折59例疗效分析[J].上海口腔医学,2004,13(3):227-229. 被引量:8
  • 2孙玉华,唐友盛,徐兵.颌面部骨折固定中的生物力学研究[J].上海口腔医学,2005,14(1):86-89. 被引量:13
  • 3张晓,张熙恩,张震康.小型金属板坚固固定在正颌外科的应用[J].中华口腔医学杂志,1995,30(3):184-186. 被引量:8
  • 4何军,宋小顺.小型钛板坚固内固定治疗下颌骨骨折36例[J].第四军医大学学报,2006,27(9):780-780. 被引量:3
  • 5Ellis E Ⅲ, Miles BA. Fractures of the mandible: a technical perspective. Plast Reconstr Surg, 2007, 120 (7) : 76s - 89s.
  • 6Miloro M. Peterson~ principles of oral and maxillofacial surgery. 2nd ed. London: BC Decker Inc, 2004, 371 -382.
  • 7Ellis E Ⅲ. Use of a 2. 0 - mm locking plate/screw system for mandibular fracture surgery. J Oral Maxillofac Surg, 2002, 60(6 ) : 642 - 645,.
  • 8Herford AS, Ellis E. Use of a locking reconstruction bone plate/ screw system for mandibular surgery. J Oral Maxillofac Surg, 1998, 56(11) : 1261 - 1265.
  • 9Haug RH, Street CC, Goltz M. Does plate adaptation affect stability? A biomechanlcal comparison of locking and nonloeking plates. J Oral Maxillofac Surg, 2002, 60(11) : 1319 -1326.
  • 10Gellrieh NC, Suarez Cunqueiro MM, Otero Gepeda XL, et al. Comparative study of locking plates in mandibular reconstruction after ablative tumor surgery: THORP versus Unilock system. J Oral Maxillofac Surg, 2004, 62(2): 186 -193.

共引文献38

同被引文献51

  • 1沈志浩,费伟,李铮,尹明平,廖楚航.颌骨骨折坚强内固定术97例应用体会[J].口腔颌面外科杂志,2007,17(2):168-169. 被引量:36
  • 2Taglialatela SC. Mucoceles as a complication of submandibular intu- bation [ J ]. J Graniomaxiuofac Surg, 2004,32 ( 5 ) : 335.
  • 3Cox T, Kohn MW, Impelluso T. Computerized analysis of resorbable polymer plates and screws for the rigid fixation of mandibular angle fractures. J Oral Maxillofac Surg. 2003; 61 (4): 481-487; discussion 487-488.
  • 4Wagner A, Krach W, Schicho K, et al. A 3-dimensional finite-element analysis investigating the biomechanical behavior of the mandible and plate osteosynthesis in cases of fractures of the condylar process. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2002;94(6):678-686.
  • 5Hahn M, Nassutt R, Delling G, The influence of material and design features on the mechanical properties of transpedicular spinal fixation implants. J Biomed Mater Res. 2002:63(3):354-362.
  • 6Hart RT, Hennebel VV, Thongpreda N, et al. Modeling the biomechanics of the mandible: a three-dimensional finite element study. J Biomech. 1992;25(3):261-286.
  • 7Ellis E 3rd, Walker L. Treatment of mandibular angle fractures using two noncompression miniplates. J Oral Maxillofac Surg. 1994;52(10):1032-1036; discussion 1036-1037.
  • 8Motamedi MH. An assessment of maxillofacial fractures: a 5-year study of 237 patients. J Oral Maxiilofac Surg. 2003; 61(1): 61-64.
  • 9Zachariades N, Mezitis M, Mourouzis C, et al. Fractures of the mandibular condyle: a review of 466 cases. Literature review, reflections on treatment and proposals. J Craniomaxillofac Surg. 2006;34(7):421-432.
  • 10Roccia F, Boffano P, Bianchi FA, et al. An 11-year review of dental injuries associated with maxillofacial fractures in Turin, Italy. Oral Maxillofac Surg. 2013;17(4):269-274.

引证文献7

二级引证文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部