对光纤法布里-珀罗(F-P)腔长偏振互相关解调法中的双折射光楔进行了理论和实验研究,建立了双折射光楔对干涉光程差影响的数学模型,并进行了数值仿真。仿真结果表明,当楔角为4°时,要保证楔面内任意点处的光程误差在15nm以内,入射角应小于0.3°,光楔光轴倾斜应小于0.8°,楔面垂直度误差应小于0.15°。采用光楔进行了偏振光干涉实验,实验干涉条纹与理论条纹基本一致,实验干涉条纹的倾斜度与理论倾斜度相差0.02°。
The effects of the birefringent wedges in the cross-correlation polarization demodulation system of optical fiber Fabry-Pérot sensors are analyzed.A mathematical model for the optical path difference is established based on the results of the incident angle,optical axis and oblique of the wedge surface.The error of the optical path difference between the theoretical model and the simple model is simulated.The analysis results indicate that the error of the simple model for optical wedges is less than 15 nm only if the incident angle is less than 0.3°,and the optical axis is less than 0.8°and the vertical error of the wedge surface is less than 0.15°,when the wedge angle is 4°.The fringes of the experiment based on polarized light interference with the birefringent wedge are mostly consistent with the theoretical fringes.The slope difference between the experimental fringes and the theoretical fringes is 0.02°.
出处
《光电子.激光》
EI
CAS
CSCD
北大核心
2012年第1期67-73,共7页
Journal of Optoelectronics·Laser
基金
国家“973”计划(2010CB327802)
国家自然科学基金(11004150)
天津市科技支撑重点项目(11ZCKFGX01900)
教育部博士点新教师基金(200800561020)
中国博士后科学基金(201003298)
教育部留学回国人员科研启动基金
深圳市传感器技术重点实验室开放基金(SST201013)资助项目
关键词
法布里-珀罗(F-P)
白光干涉
双折射光楔
偏振互相关解调
光程差
Fabry-Pérot(F-P)
white-light interference
birefringent wedge
cross-correlation polarization demodulation