摘要 研究渐进性引导呼吸对呼吸性窦性心率不齐(RSA)的影响。对15名健康成年男性采集引导呼吸率依次为【14次/min—12.5次/min—11次/min—9.5次/min—8次/min—7次/min】状态下的同步心电、呼吸信号,采用提取RSA时、频特征参数的方法来研究渐变性呼吸率对RSA的影响。计算结果显示:表征RSA强度的三个特征参数总体上随着呼吸率的逐渐降低均呈现出增大的变化趋势。RSA代表着呼吸系统对心血管系统的反射调控,此实验结果表明,随着呼吸率的降低,呼吸系统对心血管系统的反射调控作用逐渐增加,提示可通过改变呼吸模式来改善心血管系统的功能。 To investigate the effects of gradually guided breathing on respiratory sinus arrhythmia(RSA),15 healthy men's simultaneous ECG and respiratory signals during the guided breathing process(14 beats/min—12.5 beats/min—11 beats/min—9.5 beats/min—8 beats/minute—7 beats /min)were acquired.Based on the frequency domain and time domain methods,the effects of respiratory rate on RSA were studied.A general tendency increase features the three parameters of RSA as respiratory rate decreased.RSA represents the reflection control of respiratory system to cardiovascular system.The results suggested that the function of the reflection control of respiratory system to cardiovascular system increaseed with guided breathing decreasing.The conclusion indicates that the cardiovascular system could be improved by regulating the mode of respiration.
出处 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2012年第1期45-50,69,共7页 Journal of Biomedical Engineering
基金 国家自然科学基金青年基金资助项目(60801009) 国家自然科学基金资助项目(60971044) 北京市自然科学基金资助项目(3102028)
关键词 引导呼吸 呼吸性窦性心率不齐 呼吸率 心血管 Guided breathing Respiratory sinus arrhythmia(RSA) Respiratory rate Cardiovascular
  • 相关文献

参考文献2

二级参考文献8

  • 1[1]Uwe B K(o)hler,Hennig C,Orglmeister R.The principles of software QRS detection.IEEE Engineering in Medicine And Bilogy,January/February2002:42 -52
  • 2[2]F G M,Jadallah M A,et al.A Comparison of the noise sensitiyity of nine QRS detection algorithms.IEEE Transactions on Biomedical Engineering,1990; 37(1):85-97
  • 3Clarenbach CF,Senn O,Brack T,et al.Monitoring of ventilation during exercise by a portable respiratory inductive plethysmograph[J].Chest,2005,128(3):1282-1290.
  • 4Goldberg HD,Goldberg MI.Deformable pick-up coil and cooperating magnet for measuring physical quantities with means for rendering coil output independent of orientation[P].US Patent,3731184,1973.
  • 5Cohen KP,Panescu D,Booske JH,et al.Design of an inductive plethysmograph for ventilation measurement[J].Physiol Meas,1994,15(2):217-229.
  • 6Watson HL,Poole DA,Sackner MA.Accuracy of respiratory inductive plethysmographic cross-sectional areas[J].Appl Physiol,1988,65(1):306-308.
  • 7Konno KJ.Mead measurement of the separate volume changes of rib cage and abdomen during breathing[J].Appl Physiol,1967,22(3):407-422.
  • 8Sackner MA,Watson H,Belsito AS,et al.Calibration of respiratory inductive plethysmograph during natural breathing[J].Appl Physiol,1989,66(1):410-420.