期刊文献+

反激变换器共模传导EMI噪声抑制的研究

Research on CM EMI Suppression in Flyback Converter
下载PDF
导出
摘要 对反激式变换器的原、副边共模传导EMI噪声特点进行了分析,总结了共模传导噪声模型并详细介绍了干扰源、传输通道对共模传导噪声的影响。建模分析了变压器绕组分布电容与共模传导等效电容之间的关系,针对原、副边共模噪声的特点,提出通过调整变压器绕组层间距离来控制共模传导路径阻抗特性的新方法,实现原、副边共模电流的抵消,从而更好地抑制共模传导噪声。并以一台40W的反激式电源为实验平台,用实验方法验证了该方案的可行性。 Common-mode (CM) conducted noise characteristic of flyback converter was analyzed. A model of CM conducted noise was concluded. The influence of CM noise sources and its conduction paths on CM noise were introduced with circumstance. The relationship between the equivalent CM capacitance of transformer and the stray capacitance was analyzed detaileclly. A new solution adjusting the distance between the primary winding and the second winding to repress the CM conducted noise was proposed. The experiments carried based on a 40W flyback converter verify the validity of the new solution.
作者 许远 董纪清
出处 《电源学报》 2012年第1期37-40,共4页 Journal of Power Supply
基金 福州大学科技发展基金资助项目(2010-XQ-04)
关键词 反激变换器 绕组层间距离 共模传导EMI flyback converter distance between primary winding and second winding CM conducted EMI
  • 相关文献

参考文献3

二级参考文献21

  • 1林思聪,陈为.反激式开关电源共模传导发射模型的分析与应用[J].电气应用,2005,24(2):119-122. 被引量:5
  • 2和军平,陈为,姜建国.开关电源共模传导干扰模型的研究[J].中国电机工程学报,2005,25(8):50-55. 被引量:40
  • 3赵志英,秦海鸿,龚春英.变压器分布电容对高频高压反激变换器的影响及其抑制措施[J].电工电能新技术,2006,25(4):67-70. 被引量:15
  • 4冯江涛 杨志辉 陈为.变压器屏蔽对开关电源电磁干扰(EMI)影响的分析[A].台达电力电子研发中心.2002年会论文集[C].上海,2002..
  • 5Kchikack M, Yuan Y S. Simple modeling for conducted common-mode current in switching circuits. Proc. of IEEE PESC2001. Vancouver, Canada. 2001,1(16):91~95.
  • 6Okyere P F, Heinemann L. Computer-aided analysis and reduction of conducted EMI in switched-mode power converter, Proc. of IEEE APEC98. Anahein, USA.1998,2(7):924~928.
  • 7PhilipP Okyere,L Heinemann. An advanced SPICE-compatible model for high frequency multiwinding transformers. Proc. of IEEE PESC99. Charleston, USA. 1999,1(7):592~597.
  • 8R Asensi,J A Cobos. A full procedure to model high frequency transformer windings. PESC'94 Record. Taipei,Taiwan. 1994,2(6):856~863.
  • 9Gonzalez D, Gago J, Balcells J. New simplified method for the simulation of conducted EMI generated by switched power converters[J]. IEEE Trans on Industry Electronics. 2003, 50(6): 1078-1084.
  • 10Lee Dong-Young, Lee J H, Min S H et al. Exact simulation ofconducted EMI in switched mode power supplies[C]. 34th International Energy Conversion Engineering Conference, 1999,Vancourer Canada.