摘要
建立了以正己烷为溶剂、超声波震荡提取、气相色谱-质谱联用仪测定火场残留汽油中8种目标化合物的方法。各组分的浓度在0.1~50μg/mL范围内具有良好的线性,线性相关系数r2大于0.995,测定结果的标准偏差(n=7)小于5%。实际样品的测量结果表明,未烧汽油样品中甲苯含量高于其它7种目标化合物,在燃烧残留地毯中,仅可检验出3种目标化合物,而燃烧残留水泥块中可检出8种目标化合物。
A method of gas chromatography-mass(GC-MS) spectrometry was developed for the quantitative analysis of gasoline trace in fire debris.Eight compounds,such as aromatic hydrocarbons,n-alkane and naphthalene,were selected as target compounds for quantitative analysis.The results showed that the linear range of eight compounds was 0.1~50 μg/mL with correlation coefficients r2 more than 0.995.The relative standard deviation(n=7) was less than 5%.Fire debris analysis indicated toluene showed the highest content in fresh gasoline.Three compounds were detected in carpet residues after burning,while eight compounds were detected in cement bricks.
出处
《中山大学学报(自然科学版)》
CAS
CSCD
北大核心
2012年第1期59-62,共4页
Acta Scientiarum Naturalium Universitatis Sunyatseni
基金
广东省消防科学技术重点实验室基金资助项目(2010A060801010)