摘要
对一起机车误上码从产生原因和机理上进行了初步研究与分析,认为邻线电磁感应干扰是导致机车误上码的根本原因,并进行了相关计算,且对如何消除误上码现象提出了改进建议。
Through a preliminary analysis of the cause and mechanism of a case of locomotive code error,it is concluded that the electromagnetic induction interference from neighboring lines are the root cause of the code error,and the related calculation is made,and suggestions on how to eliminate the code error is proposed.
出处
《铁道通信信号》
2012年第2期26-28,共3页
Railway Signalling & Communication
关键词
电磁感应
机车信号
升级显示
研究
分析
Electromagnetic induction
Locomotive signal
Upgrading display
Research
Analysis