摘要
对UNITROL5000型励磁系统冷却电源回路存在问题进行分析,确定冷却电源回路改造方案,该方案在黄岛发电公司实施后消除了机组的安全隐患。
This article has developed a simple and reliable cooling power loop transformation plan, based on the analysis of the cooling power circuit of UNITROL5000 type excitation system and its existing problems. The scheme eliminates the potential safety hazard in the unit of Huangdao power company.
出处
《山东电力技术》
2012年第1期55-56,60,共3页
Shandong Electric Power
关键词
励磁系统
冷却电源
改造方案
excitation system
cooling power
transformation plan